1.2 Restrictions on Combinations and Functions
Input signals of Control Unit
I/O
Pulse output function
No.
CH0 J-point control positioning
X0
control start input
CH1 J-point control positioning
X1
control start input
X2
CH4 Home input
X3
CH5 Home input
X4
CH0 Home input
X5
CH1 Home input
X6
CH2 Home input
X7
CH3 Home input
Output signals of Control Unit
Pulse output function
I/O
No.
Pulse output
Y0
CH0 CW or pulse output
Y1
CH0 CCW or sign output
Y2
CH1 CW or pulse output
Y3
CH1 CCW or sign output
Y4
CH2 CW or pulse output
Y5
CH2 CCW or sign output
Y6
CH3 CW or pulse output
Y7
CH3 CCW or sign output
Y8
CH4 CW or pulse output
Y9
CH4 CCW or sign output
YA
CH5 CW or pulse output
YB
CH5 CCW or sign output
YC
-
YD
-
YE
-
YF
-
Y10
-
Y11
-
Y12
-
Y13
-
1-6
High-speed counter function
Count input
Single-phase
2-phase
CH0 Count input
CH0 Count input
CH1 Count input
CH2 Count input
CH2 Count input
CH3 Count input
CH4 Count input
CH4 Count input
CH5 Count input
CH6 Count input
CH6 Count input
CH7 Count input
Deviation counter clear output
-
-
-
-
CH0 (C14 type)
CH1 (C14 type)
-
-
CH0 (C30 type)
CH1 (C30 type)
CH2 (C30 type)
CH3 (C30 type)
CH0 (C60 type)
CH1 (C60 type)
-
-
CH2 (C60 type)
CH3 (C60 type)
CH4 (C60 type)
CH5 (C60 type)
Reset input
-
-
-
-
-
-
CH0 Reset input
CH2 Reset input
PWM output function
CH0 PWM output
(Note 2)
CH1 PWM output
(Note 2)
CH2 PWM output
(Note 2)
CH3 PWM output
(Note 2)
-
-
-
-
-
-
-
-
-
-