Panasonic FP-XH Series User Manual page 169

Programmable controller
Hide thumbs Also See for FP-XH Series:

Advertisement

Code
Value
Target value 3: ON set
(f)
value
Target value 2: ON set
(g)
value
Target value 1: ON set
(h)
value
(1)
Execution condition
High-speed counter
instruction
(2)
active flag
(3)
Cam output
Interrupt program
(4)
activation
Sample program
Code
Description
(1)
High-speed counter channel H10: Performs the upper limit control, CH0
(2)
Cam output device type K1: Internal relay (R)
(3)
Word number of cam output device K10
(4)
Specification of the number of target values K3
(5)
Target value 1: ON set value K1000
(6)
Target value 1: OFF set value K7000
(7)
Target value 2: ON set value K3000
WUME-FPXHPOSG-01
10.4 High-speed Counter Cam Control Instruction
Description
When the execution condition turns ON from OFF, the instruction is executed
and the cam control starts.
The high-speed counter instruction active flag turns ON during the execution
of the instruction.
The output turns ON/OFF according the set values.
In the case of subtraction, when the elapsed value falls below the OFF set
value, the interrupt program is started.
10-29