5.2 JOG Operation
5.2 JOG Operation
5.2.1 Settings and Operation of JOG Operation
The parameters for JOG operations are specified in the positioning parameter setting menus of
Configuration PMX.
Pulses are output while the JOG operation start instruction (F381 JOGST) is executed.
Reverse JOG
Ball screw
(-) side
Operation diagram
20,000Hz
Instruction start condition
Busy signal
Operation done signal
JOG operation target speed
Operations of each contact
● The BUSY flags (X28 to X2D), which indicate that the motor is running, will turn ON when the
JOG operation starts, and they will turn OFF when the operation completes.
● The operation done flags (X30 to X35), which indicate the completion of operation, will turn
ON when the current operation is completed, and they will be held until the next positioning
control, JOG operation or home return operation starts.
Notes on programming
● The startup contact and flag numbers vary depending on channel numbers (axis numbers).
5-4
Table
f [Hz]
1,000Hz
100ms
20,000
Forward JOG
(+) side
t [ms]
200ms