Precautions during programming
● When the control code (low byte) is H20 to H27 (home return mode I), the home input is
enabled even after the near home input, the completion of deceleration, or in the middle of
deceleration.
● When the control code (low byte) is H30 to H37 (home return mode II), the home input is
enabled only after the near home input and the completion of deceleration up to the value of
initial speed.
● Even when the home input is enabled, the pulse output starts by the execution of this
instruction.
● When the near home input is enabled during acceleration, the deceleration operation will
start.
● When describing the same channel in both the normal program and the interrupt program, be
sure to program not to execute them simultaneously.
● This instruction cannot be executed when a control active flag corresponding to each
channel is ON.
● Select "Pulse output" for the channel setting corresponding to the system register no. 402.
● By performing the rewriting during RUN while outputting pulses, more pulses than the setting
may be output.
● For performing the software reset, disabling the counting, stopping the pulse output or near
home processing, refer to the F0 (MV) instruction, pulse output control.
● For details of the allocations of I/O and flags, refer to "Allocation of Memory Areas".
REFERENCE
11.2.2 When Using Pulse Output Function (FP-X Compatible Instruction Mode)
7.2.3 [F172 (PLSH)] Pulse Output (JOG operation)
This instruction outputs pulses from a specified pulse output channel according to specified
parameters.
Instruction format
Operand
Operand
Settings
S
Starting number of the area in which data tables are registered
n
Target channel for pulse output
WUME-FPXHPOSG-01
7.2 FP-X Compatible Instruction Mode Control Instruction
7-19