7.2 FP-X Compatible Instruction Mode Control Instruction
● When the frequency after the second step is 0 or outside of the settable range, the pulse
output stops.
● When the table pointer exceeds the area of data registers DT during the pulse output, the
pulse output control will be canceled and the control active flag will turn OFF.
● The target values should be set in the range shown on the next page. If a value outside of
the range is specified, the number of pulses different from the specified value is output.
● For details of the allocations of I/O and flags, refer to "Allocation of Memory Areas".
REFERENCE
11.2.2 When Using Pulse Output Function (FP-X Compatible Instruction Mode)
7.2.5 [F175 (SPSH)] Pulse Output (Linear Interpolation)
Pulses are output from channel for 2 pulse output, in accordance with the parameters in the
designated data table, so that the path to the target position forms a straight line.
Instruction format
Operand
Operand
Settings
S
Starting number of the area in which data tables are registered
n
0 or 2
Memory area type that can be specified
Operand
WX
S
-
n
-
Outline of operation
● Outputs pulses from a specified channel when a corresponding control active flag is OFF
and the execution condition is ON.
● The control code, initial speed, maximum speed, acceleration / deceleration time, and target
value are specified by creating data tables [S] to [S+11] described on the next page using a
user program.
7-26
WY
WR
WL
SV
-
-
-
-
-
-
EV
DT
LD
-
-
-
-
-
-
-
Constant
Index
I
modifier
K
H
-
-
-
-
WUME-FPXHPOSG-01
-