Download Print this page

Panasonic FP-XH Series User Manual page 176

Programmable controller
Hide thumbs Also See for FP-XH Series:

Advertisement

11.1 Specifications
Item
Speed command range
Acceleration / deceleration
method
Acceleration time
Deceleration time
Return method
Deceleration stop
Emergency stop
Limit stop
System stop
Memory backup
(Note 1)
The J-point control can be executed only for the two axes of CH0 and CH1.
(Note 2)
When performing the J-point control or JOG operation, the speed can be changed after the startup.
11-4
Table setting mode
Pulse: 1 to 100,000 Hz
Linear acceleration / deceleration
1 to 10,000 ms (Settable by 1 ms)
1 to 10,000 ms (Settable by 1 ms)
DOG methods (3 types), Home
return method, Data set method
Each axis stops in the deceleration
time of a running operation.
Each axis stops in the deceleration
time specified in the positioning
parameter.
Each axis stops in the deceleration
time specified for the over limit input.
All axes stop.
Positioning parameters and
positioning table data are stored in
F-ROM
(without battery).
Specifications
FP-X compatible instruction mode
DOG method x 1, Home return
method x 1
Selected by F171 instruction
Each axis stops in the deceleration
time of a running operation.
(Executed by F0 instruction)
Data is stored in arbitrary data
registers by user programs.
WUME-FPXHPOSG-01

Advertisement

loading