Sample program
(1)
Positioning operation is running
(2)
Positioning operation starts
(3)
Resets the elapsed value of the high-speed counter CH0.
Target value match OFF instruction: Y0 turns OFF when the elapsed value of the high-speed counter
(4)
reaches 5000 pulses.
(5)
Sets the inverter operation signal Y0.
(6)
Positioning done pulse (0.5 sec)
(7)
Sets 0.5 sec with 0.1-second timer.
10.3.5 Sample Program (Positioning Operation With Inverter: Double-Speed)
Counts the feedback signals from the encoder with the high-speed counter. Switches the
inverter operation to low speed operation when the count value reaches 4500. The operation of
the inverter stops when the count value reaches 5000.
WUME-FPXHPOSG-01
10.3 High-speed Counter Instruction
10-17