Download Print this page

Panasonic FP-XH Series User Manual page 107

Programmable controller
Hide thumbs Also See for FP-XH Series:

Advertisement

Operand
(3)
S+6, S+7
(4)
S+8, S+9
(5)
S+10, S+11 K0
Example of program
7kHz
1kHz
300ms
⊿f
⊿t
WUME-FPXHPOSG-01
7.2 FP-X Compatible Instruction Mode Control Instruction
Settings
Description
When the initial speed is set to low speed, an operation error occurs if
a value exceeding K22000 is specified for the maximum speed.
Acceleration / deceleration time (ms)
With 30 steps: K30 to K32760
Acceleration /
With 60 steps: K60 to K32760
deceleration time
t (ms)
(Note 1)
Target value
Target value
K-2147483648 to K2147483647 pulse
Set K0 to the last two words of the data table.
No. of output pulses
100,000
(Specify in 30 ms increments.)
(Specify in 60 ms increments.)
When the time is not specified in 30 ms nor 60 ms
increments, it will be automatically corrected to the
multiple value (larger value) of 30 ms or 60 ms.
300ms
7-13

Advertisement

loading