10.4 High-speed Counter Cam Control Instruction
Operand
Settings
Starting word no. of
S+4, S+5
output device
S+6, S+7
No. of target values
Target value 1: ON set
S+8, S+9
value
Target value 1: ON set
S+10, S+11
value
Target value 2: ON set
S+12, S+13
value
Target value 2: ON set
S+14, S+15
value
------
------
S+(m-1)x4+8
Target value m: ON set
value
S+(m-1)x4+9
S+(m-1)x4+10
Target value m: OFF
set value
S+(m-1)x4+11
S+(m-1)x4+12
Upper limit
S+(m-1)x4+13
(Note 1)
When specifying the output relay (Y), values are also output to the Control Unit output as well as
operation memories.
(Note 2)
When the number of target values [S+6, S+7] is set to 1-16, the cam output is allocated to one word of
output device. When set to 17-32, it is allocated to two words of output device. Refer to the next page
for details.
(Note 3)
The number of target values specified after [S+8, S+9] varies according to the number of target values
specified in [S+6, S+7].
(Note 4)
The upper limit of the data table end is valid only when the upper limit control is set to "Yes" in [S, S
+1]. This setting can be omitted when the upper limit control is set to "No".
(Note 5)
The data table varies in the range of 12 to 138 words according to the number of target values and the
specified upper limit setting
Specification of output device: [S+2] to [S+5]
● When the number of target values is set to 1-16, one word is used. When the number of
target values is set to 17-32, two words are used.
● One device is allocated to a paired target values (ON set value and OFF set value).
(Example): When the output device type is set to "Internal relay", the starting word number
of output device is set to "0", and the number of target values is set to "32", R0 to R1F are
allocated as the device for the cam output.
10-22
Description
Specify the starting word number of the device set for the cam
(Note 2)
output.
Settable range: K1 to K32
Set the ON set value and OFF set value according to the number of
target values.
(Note 3)
Settable range:
K-2147483647 to K2147483646 (H80000001 to H7FFFFFFE)
The cam output described in the next page is acquired according to
the magnitude of the ON set values and elapsed value.
Settable range:
(Note 4)
K1 to K2147483646 (H1 to H7FFFFFFE)
(Note 2)
WUME-FPXHPOSG-01