7.2 FP-X Compatible Instruction Mode Control Instruction
REFERENCE
11.2.2 When Using Pulse Output Function (FP-X Compatible Instruction Mode)
7.2.4 [F174 (SP0H)] Pulse Output (Selectable Data Table Control Operation)
This instruction outputs pulses from a specified pulse output channel according to a specified
data table.
Instruction format
Operand
Operand
Settings
S
Starting number of the area in which data tables are registered
n
Target channel for pulse output
Memory area type that can be specified
Operand
WX
S
-
n
-
Outline of operation
● Outputs pulses from a specified channel according to the settings specified in the data table
starting with the address specified by [S] when a corresponding control active flag is OFF
and the execution condition is ON.
● Switches the pulse frequency when the elapsed value of the high-speed counter reaches the
target value set in the data table. (It is performed by the interrupt processing.)
● Stops the pulse output when the elapsed value reaches the final target value.
● For setting the frequency to 50 kHz or more, specify the duty of 1/4 (25%).