7.2.7

Pull-Ups

The AGP 2.0 Specification requires AGP control signals to have pull-up resistors to VDDQ to
ensure they contain stable values when no agent is actively driving the bus. Also, the
AD_STB[1:0]# and ST_STB# strobes require pull-down resistors to GND. The Intel 855GME
chipset GMCH has integrated many of these pull-up/pull-down resistors on the AGP interface and
a few other signals not required by the AGP 2.0 Specification. Pull-ups are allowed on any signal
except AD_STB[1:0]# and SB_STB#.
The Intel chipset GMCH has no support for the PERR# and SERR# pins of an AGP graphics
controller that supports PERR# and SERR#. Pull-ups to a 1.5-V source are required down on the
motherboard in such cases.
Table 64. AGP Pull-Up/Pull-Down Requirements and Straps
Signal
DEVSEL#
FRAME#
GNT#
INTA#
INTB#
IRDY#
PERR#
PIPE#
RBF#
REQ#
SERR#
ST[2:0]
STOP#
TRDY#
WBF#
AD_STB[1:0]
AD_STB[1:0]#
SB_STB
SB_STB#
SBA[7:0]
NOTES:
1. The Intel chipset GMCH has integrated pull-ups to ensure that these signals do not float when there is no
add-in card in the connector.
2. The Intel chipset GMCH does not implement the PERR# and SERR# signals. Pull-ups on the motherboard
are required for AGP graphics controllers that implement these signals.
3. The Intel chipset GMCH does not implement interrupt signals. AGP graphics controller's INTA# and INTB#
signals must but routed to the system PCI interrupt request handler where the pull-up requirement should be
met as well. For 855GME/ICH4 chipset-based systems, they can be routed to the ICH4's PIRQ signals that
are open drain and require pull-ups on the motherboard.
4. ST[1:0] provide the strapping options for 100-MHz PSB operation and DDR memory, respectively.
5. INTA# and INTB# should be pulled to 3.3 V, not VDDQ.
6. The pull-up/pull-down resistor value requirements are shown in
180
®
82801DB ICH4 Embedded Platform Design Guide
AGP 2.0 Signal Pull-Up/
Pull-Down Requirements
Pull-Up
Pull-Up
Pull-Up
Pull-Up
Pull-Up
GMCH Integrated Pull-Up/
Pull-Down
Pull-Up
Pull-Up
Pull-Up
Pull-Up
Pull-Up
Pull-Up
Pull-Up
Pull-Down
Pull-Up
Pull-Up
Pull-Up
Pull-Up
Pull-Down
Pull-Up
Pull-Down
Pull-Up
Table
65.
Notes
3, 5
3, 5
2
1
2
4
1
Design Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

6300esb

Table of Contents