16 Operating Parameters
16.6 Administrative
Data Format
on Bus
Float32
(2 registers)
Int16
(1 register)
Int16_Ung8000
(1 register)
UInt16
(1 register)
UInt32
(2 registers)
428
Description
Setting Range
IEEE Float value
-10
16-bit signed
- 32 768 to +32 768
integer
16-bit signed
-32768 bis +32768
integer
16-bit integer,
0 to +65 535

0
32-bit integer,
0 to +4 294 967 295

0
Invalid
recognition
38
38
to +10
NaN = invalid
INF = overflow
none
-32768 (8000h)
= ungültig
none
none
E50417-H1040-C522-A6, Edition 06.2019
Used by (example)
SENTRON PAC3x00,
SICAM AI 7XV5674,
SICAM T 7KG966,
SICAM P50 7KG775
SENTRON 3WL/3VL
SICAM P50 7KG775
SIPROTEC 4
SENTRON 3WL/3VL
SIPROTEC 4,
SENTRON 3WL/3VL
SICAM Q100, 7KG95xx, Device Manual