The mapping file can be opened in a spreadsheet program. The following figure shows an example:
Figure 9-67
The mapping file includes 6 columns, see the following table:
Table 9-26
Column
Name
Unit
Transmit [0,1]
SICAM Q100, 7KG95xx, Device Manual
E50417-H1040-C522-A6, Edition 06.2019
Example of Mapping File
Columns in the Mapping File
Value
Fixed
Fixed
0
1
Description
Name of the data point in IEC 61850 compatible syntax.
Note that the prefix for 10/12 cycles values (refer to Table 9-
27) is always shown even when the data point is configured
as an aggregated value.
If there are phase-related data points (for example, phsA,
phsB, phsC for PhV), only the first data point is shown and the
configured values for phsA are automatically taken over as
the data points for the other phases.
The unit of the measured value
0 = not transmitted
1 = transmitted
This column shows whether the data point is transmitted or
not.