No-Protocol Communications - Omron CP1L-EL20DR-D Operation Manual

Sysmac cp series cp1l-el/em cpu unit
Table of Contents

Advertisement

Serial Communications
Protocol
Peripheral
CX-Programmer
bus (toolbus)
RS-232C
SYSMAC
CP1L
COM
01
03
05
NC
00
02
04
POWER
RUN
ERR/ALM
INH
LNK/ACT
BKUP
1
00
01
ANALOG INPUT
COM(V+)
V1+ V2+ COM
MAC Address:
01234567890A
1:1 NT Links OMRON PTs (Programmable Terminals)
NS-series PT
RS-232C
SYSMAC
CP1L
COM
01
03
05
07
NC
00
02
04
06
POWER
RUN
ERR/ALM
INH
LNK/ACT
BKUP
1
00
01
02
ANALOG INPUT
COM(V+)
V1+ V2+ COM
MAC Address:
01234567890A
1:1 Links
CP1L-EL/EM CPU Unit
SYSMAC
CP1L
COM
01
03
05
07
09
NC
00
02
04
06
08
10
POWER
RUN
ERR/ALM
INH
LNK/ACT
BKUP
1
00
01
02
03
04
ANALOG INPUT
COM(V+)
COM
V1+ V2+ COM
MAC Address:
01234567890A
8-3-2

No-protocol Communications

402
Connected devices
Personal computer running
the CX-Programmer
07
09
11
01
03
05
07
09
11
06
08
10
00
02
04
06
08
10
Peripheral bus (toolbus)
2
02
03
04
06
00
01
03
04
06
COM
05
07
COM
02
COM
05
07
09
11
01
03
05
07
09
11
08
10
00
02
04
06
08
10
2
03
04
06
00
01
03
04
06
COM
05
07
COM
02
COM
05
07
SYSMAC
CP1L
11
01
03
05
07
09
11
COM
01
03
05
07
09
11
01
03
05
07
09
11
00
02
04
06
08
10
NC
00
02
04
06
08
10
00
02
04
06
08
10
POWER
RUN
ERR/ALM
INH
LNK/ACT
BKUP
2
1
2
06
00
01
03
04
06
00
01
02
03
04
06
00
01
03
04
06
ANALOG INPUT
05
07
COM
02
COM
05
07
COM(V+)
COM
05
07
COM
02
COM
05
07
V1+ V2+ COM
MAC Address:
01234567890A
RS-232C
1:1 Link
No-protocol communications enable sending and receiving data using the
TRANSMIT (TXD(236)) and RECEIVE (RXD(235)) instructions without using
a protocol and without data conversion (e.g., no retry processing, data type
conversion, or process branching based on received data). The communica-
tions mode for the serial port must be set for no-protocol communications in
the PLC Setup.
No-protocol communications are used to send data in one direction to or from
standard devices that have an RS-232C or RS-422A/485 port using TXD(236)
or RXD(235).
Provides high-speed communi-
cations with the CX-Program-
mer.
Enables data exchange with a
PT without communications
programming in the CPU Unit.
(The 1:N NT Link protocol is
used for communications even
for 1:1 connections.)
Enables linking data in a 64-
word Link Area between two
CP1L-EL/EM CPU Unit
PLCs connected by an RS-
C-series CPU Unit
232C cable.
CPM1A-V1
CPM2
CQM1H
C200HX/HG/HE
Section 8-3
Description
Serial
port 1
OK
OK
OK
Serial
port 2
OK
OK
OK

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents