I/O Wiring; Range Comparison Table Settings - Omron CP1L-EL20DR-D Operation Manual

Sysmac cp series cp1l-el/em cpu unit
Table of Contents

Advertisement

High-speed Counters
Upper Terminal Block
Bottom terminal block
(Example: Relay Output
Models)

I/O Wiring

Input Wiring
+
-
COM
00
NC
Measurement
start switch
Output Wiring
PL1
NC
00
NC
COM

Range Comparison Table Settings

The inspection standards data is set in the DM Area with the CX-Programmer.
Even though range 1 is the only range being used, all 40 words must still be
dedicated to the range comparison table.
Word
Setting
D10000
7430
D10001
0000
D10002
765C
D10003
0000
D10004
000A
D10005 to
All 0000 Range 2 lower and upper limit values
D10008
D10009
FFFF
01
03
05
07
09
11
02
04
06
08
10
CIO 100
PL1: OK indicator
PL2: NG indicator
PL2
04
06
01
02
03
COM COM COM
05
07
CIO 100
Function
Rightmost 4 digits of range 1 lower limit
Leftmost 4 digits of range 1 lower limit
Rightmost 4 digits of range 1 upper limit
Leftmost 4 digits of range 1 upper limit
Range 1 interrupt task number = 10 (A hex)
(Not used and don't need to be set.)
Disables range 2.
~
Section 7-1
01
03
05
07
09
00
02
04
06
08
10
CIO 101
00
01
03
04
06
COM
COM
02
05
07
CIO 101
Lower limit value:
30,000
Upper limit value:
30,300
Range 2 settings
11
231