Omron CP1L-EL20DR-D Operation Manual page 754

Sysmac cp series cp1l-el/em cpu unit
Table of Contents

Advertisement

Auxiliary Area Allocations by Address
Address
Name
Words
Bits
A406
All
PLC Setup
Error Location
A407
00 to 12 Too Many I/O
Points, Details
13 to 15 Too Many I/O
Points, Cause
A424
00 to 15 Error Option
Board Flags
A435
14
I/O Option
Board Run
State Flag
(CP1L-EM:
Option 1/left)
15
I/O Option
Board Run
State Flag
(CP1L-EM:
Option 2/right,
CP1L-EL:
Option 1)
A436
00 to 05 Unit Error
Flags
A437
All
Number of
Connected
Units
720
Function
When there is a setting error in the
PLC Setup, the location of that error
is written to A406 in 4-digit hexadeci-
mal.
The CPU Unit will continue operating
and the ERR/ALM indicator on the
front of the CPU Unit will flash.
(A406 will be cleared when the
cause of the error is eliminated.)
Always 0000 hex.
The 3-digit binary value of these bits
indicates the cause of the Too Many
I/O Points Error.
Note These bits will be cleared
when the error is cleared.
The bit corresponding to the option
slot turns ON when an error occurs
in an Option Board (A315.13 will be
ON).
Bit 00: Option slot 1
Bit 01: Option slot 2
Turn ON when the I/O Option Board
works normally.
Turn OFF when the I/O Option Board
is in initial state or abnormity state.
Turn ON when the I/O Option Board
works normally.
Turn OFF when the I/O Option Board
is in initial state or abnormity state.
ON when an error occurs in a CP-
series Expansion Unit or Expansion
I/O Unit.
A436.00: 1st Unit
A436.01: 2nd Unit
A436.02: 3rd Unit
A436.03: 4th Unit
A436.04: 5th Unit
A436.05: 6th Unit
CP1W-AD041/DA041, CP1W-32ER/
32ET/32ET1, CP1W-TS002 and
CP1W-TS102 are each counted as
two Units.
Stores the number of Expansion
Units and Expansion I/O Units con-
nected as a hexadecimal number.
Note This information is valid only
when a Too Many I/O Points
error has occurred. CP1W-
AD041/DA041, CP1W-32ER/
32ET/32ET1, CP1W-TS002
and CP1W-TS102 are each
counted as two Units.
Settings
Status
Status
after
at star-
mode
change
0000 to 01FF
Cleared
Cleared
hexadecimal
0000 hex
Cleared
Cleared
010: Too
Cleared
Cleared
many Expan-
sion Unit and
Expansion I/O
Unit words
011: Too
many Expan-
sion Units
and Expan-
sion I/O Units
ON: Error
Cleared
Cleared
OFF: No error
ON: I/O
---
Cleared
option board
works nor-
mally
OFF: In initial
state or
abnormity
state
ON: I/O
---
Cleared
option board
works nor-
mally
OFF: In initial
state or
abnormity
state
OFF: No error
Retained Cleared
ON: Error
0000 to 0006
Retained Cleared
hex
Appendix D
Write
Related
timing
flags, set-
tup
tings
Refreshed
A402.10
when error
occurs.
---
A401.11,
A407.13
to
A407.15
Refreshed
---
when error
occurs.
---
A353.13
When I/O
---
option
board state
changes.
When I/O
---
option
board state
changes.
---
---
---
---