Omron CP1L-EL20DR-D Operation Manual page 448

Sysmac cp series cp1l-el/em cpu unit
Table of Contents

Advertisement

Serial Communications
414
Example: Polling Unit Link Method, Highest Unit Number: 3
In the following diagram, Polled Unit No. 2 is a PT or a Unit not participating in
the network, so the corresponding area in the Polling Unit is undefined.
Polling Unit
Polled Unit No.0
Local area
Polling Unit
Polled Unit
Local area
No.0
Polled Unit
(Not used.)
No.1
Undefined
(Not used.)
Polled Unit
(Not used.)
No.3
(Not used.)
(Not used.)
(Not used.)
(Not used.)
(Not used.)
(Not used.)
(Not used.)
(Not used.)
Example: Polling Unit Link Method, Number of Link Words: 10
The CPU Unit that is the Polling Unit (either CP1L-EL/EM or CJ1M) sends its
data (CIO 3100 to CIO 3109) to the same words (CIO 3100 to CIO 3109) in all
other CPU Units. The Polled Units send their data (CIO 3110 to CIO 3119) to
consecutive sets of 10 words in the Polling Unit. The Polling Units is a CP1L-
EL/EM CPU Unit in the following example, but it could also be a CJ1M CPU
Unit. (Only the first three Polled Units are shown below.)
CP1L-EL/EM CPU Unit
(Polling Unit)
SYSMAC
CP1L
COM
01
03
05
07
09
11
01
03
05
07
09
11
NC
00
02
04
06
08
10
00
02
04
06
08
10
POWER
RUN
ERR/ALM
INH
LNK/ACT
BKUP
1
2
00
01
02
03
04
06
00
01
03
04
06
ANALOG INPUT
COM(V+)
COM
05
07
COM
02
COM
05
07
V1+ V2+ COM
MAC Address:
01234567890A
Serial PLC Link Words
(CIO Area)
3100 to 3109
No.0
3110 to 3119
No.1
3120 to 3129
No.2
3130 to 3139
3140 to 3149
No.3
3150 to 3159
No.4
3160 to 3169
No.5
3170 to 3179
No.6
3180 to 3189
No.7
Polled Unit No.1
Polling Unit
Local area
(Not used.)
(Not used.)
(Not used.)
(Not used.)
(Not used.)
(Not used.)
(Not used.)
CP1L-EL/EM CPU Unit
CP1L-EL/EM CPU Unit
(Polled Unit No. 0)
(Polled Unit No. 1)
SYSMAC
SYSMAC
CP1L
CP1L
COM
01
03
05
07
09
11
01
03
05
07
09
11
COM
NC
00
02
04
06
08
10
00
02
04
06
08
10
NC
POWER
POWER
RUN
RUN
ERR/ALM
ERR/ALM
INH
INH
LNK/ACT
LNK/ACT
BKUP
BKUP
1
2
1
00
01
02
03
04
06
00
01
03
04
06
ANALOG INPUT
COM(V+)
COM
05
07
COM
02
COM
05
07
ANALOG INPUT
V1+ V2+ COM
V1+ V2+ COM
MAC Address:
MAC Address:
01234567890A
01234567890A
Serial PLC Link Words
Serial PLC Link Words
(CIO Area)
(CIO Area)
3100 to 3109
3100 to 3109
3110 to 3119
3110 to 3119
Section 8-3
Polled Unit No.3
Polling Unit
Local area
(Not used.)
(Not used.)
(Not used.)
(Not used.)
(Not used.)
(Not used.)
(Not used.)
CJ1M CPU Unit
(Polled Unit No. 2)
01
03
05
07
09
11
01
03
05
07
09
11
00
02
04
06
08
10
00
02
04
06
08
10
2
00
01
02
03
04
06
00
01
03
04
06
COM(V+)
COM
05
07
COM
02
COM
05
07
Serial PLC Link Words
(CIO Area)
3100 to 3109
3110 to 3119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents