Using Analog I/O; Writing D/A Conversion Data - Omron CP1L-EL20DR-D Operation Manual

Sysmac cp series cp1l-el/em cpu unit
Table of Contents

Advertisement

Analog I/O Units

Using Analog I/O

Writing Set Data and
Reading A/D Converted
Values
Writing D/A Conversion
Data
Note
490
Connect and wire the Unit.
Create a ladder program.
CPU Unit
Ladder program
MOV(021)
• Writes the set data.
• Reads the converted
values.
"m" is the last input word and "n" is the last
output word allocated to the CPU Unit or
previous Expansion Unit or Expansion I/O Unit.
CPU Unit
Ladder program
MOV(021)
Writes the conversion
values.
"n" is the last output word allocated to the CPU
Unit or previous Expansion Unit or Expansion I/O
Unit.
Word (n+1) can be used for either the set data or the analog output conversion
value.
• Connect the Analog I/O Unit.
• Wire to analog I/O devices.
• Analog inputs: 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC, –10 to
10 VDC, 0 to 20 mA, or 4 to 20 mA
• Analog outputs: 1 to 5 VDC, 0 to 10 VDC, –10 to 10 VDC, 0 to
20 mA, or 4 to 20 mA
• Set analog inputs as voltage or current inputs and set the
averaging function.
• Write set data to output words.
Analog I/O Unit
Analog I/O Unit
Section 9-4
Set data
Word (n+1)
Analog input 0
Word (m+1)
converted value
Analog input 1
Word (m+2)
converted value
Analog devices
• Temperature sensor
• Pressure sensor
• Speed sensor
• Flow sensor
• Voltage/current meter
• Other
(See note.)
Analog output
Word (n+1)
conversion value
Analog devices
• Adjustment equipment
• Servo Controller
• Variable speed device
• Recorder
• Other