Pulse Outputs
• The number of pulses cannot be changed.
• The frequency can be changed.
• The output mode and direction cannot be switched.
(2) SPED(885) (Continuous) to SPED(885) (Continuous)
• The frequency can be changed.
• The output mode and direction cannot be switched.
(3) SPED(885) (Independent) to ACC(888) (Independent)
• The number of pulses cannot be changed.
• The frequency can be changed.
• The acceleration/deceleration rate can be changed.
• The output mode and direction cannot be switched.
(4) ACC(888) (Independent) to ACC(888) (Independent)
or PLS2(887) to ACC(888) (Independent)
• The number of pulses cannot be changed.
• The frequency can be changed.
• The acceleration/deceleration rate can be changed. (The rate can
even be changed during acceleration or deceleration.)
• The output mode and direction cannot be switched.
(5) SPED(885) (Continuous) to ACC(888) (Continuous)
or ACC(888) (Continuous) to ACC(888) (Continuous)
• The frequency can be changed. (The target frequency can even be
changed during acceleration or deceleration.)
• The acceleration/deceleration rate can be changed. (The rate can
even be changed during acceleration or deceleration.)
• The output mode and direction cannot be switched.
(6) ACC(888) (Independent) to PLS2(887)
• The number of pulses can be changed. (The setting can even be
changed during acceleration or deceleration.)
• The frequency can be changed. (The target frequency can even be
changed during acceleration or deceleration.)
• The acceleration/deceleration rate can be changed. (The rate can
even be changed during acceleration or deceleration.)
• The output mode and direction cannot be switched.
(7) ACC(888) (Continuous) to PLS2(887)
• The frequency can be changed. (The target frequency can even be
changed during acceleration or deceleration.)
• The acceleration/deceleration rate can be changed. (The rate can
even be changed during acceleration or deceleration.)
• The output mode and direction cannot be switched.
(8) PLS2(887) to PLS2(887)
• The number of pulses can be changed. (The setting can even be
changed during acceleration or deceleration.)
• The frequency can be changed. (The target frequency can even be
changed during acceleration or deceleration.)
• The acceleration/deceleration rate can be changed. (The rate can
even be changed during acceleration or deceleration.)
• The output mode and direction cannot be switched.
Section 7-2
285