Specifications
Output Specifications
Relay Outputs (CP1W-40EDR/32ER/20EDR1/16ER/8ER)
Item
OFF delay
Circuit configuration
Note
(1) The response time is the hardware delay value. The delay set in the PLC
Setup (0 to 32 ms, default: 8 ms) must be added to this value. For the
CP1W-40EDR/EDT/EDT1, a fixed value of 16 ms must be added.
(2) Do not apply voltage in excess of the rated voltage to the input terminal.
Max. switching capacity
Min. switching capacity
Service life
Electrical
of relay
(See note.)
Mechanical
ON delay
OFF delay
Circuit configuration
Note
(1) Under the worst conditions, the service life of output contacts is as shown
above. The service life of relays is as shown in the following diagram as
a guideline.
300
200
100
50
30
20
10
5
3
2
0.1
0.2
1 ms max. (See note 1.)
IN
4.7 kΩ
IN
CO M
Item
2 A, 250 VAC (cosφ = 1),
2 A, 24 VDC (4 A/common)
5 VDC, 10 mA
Resistive
150,000 operations (24 VDC)
load
Inductive
100,000 operations (240 VAC, cosφ = 0.4)
load
20,000,000 operations
15 ms max.
15 ms max.
120 VAC resistive load
24 VDC τ = 7 ms
120 VAC cosφ = 0.4
240 VAC cosφ = 0.4
24 VDC/240 VAC resistive load
0.3 0.5 0.7 1
2
3
Contact current (A)
Section 2-2
Specification
Input LED
Internal
circuits
Specification
Output LED
OUT
Internal
OUT
circuits
COM
Switching rate: 1,800 operations/hour
5
Maximum
250 VAC: 2 A
24 VDC: 2 A
41