Auxiliary Area Allocations by Address
Addresses
Name
Word
Bits
A619
01
Serial Port 1
Settings
Changing
Flag (CP1L
EM-type
CPU Units)
02
Serial Port 2
Settings
Changing
Flag (CP1L
EM-type
CPU Units)
Serial Port 1
Settings
Changing
Flag (CP1L
EL-type
CPU Units)
A640
00
Serial Port 2
Modbus-
RTU Easy
Master Exe-
cution Bit
(CP1L EM-
type CPU
Units)
Serial Port 1
Modbus-
RTU Easy
Master Exe-
cution Bit
(CP1L EL-
type CPU
Units)
01
Serial Port 2
Modbus-
RTU Easy
Master Nor-
mal End
Flag (CP1L
EM-type
CPU Units)
Serial Port 1
Modbus-
RTU Easy
Master Nor-
mal End
Flag (CP1L
EL-type
CPU Units)
02
Serial Port 2
Modbus-
RTU Easy
Master Error
End Flag
(CP1L EM-
type CPU
Units)
Serial Port 1
Modbus-
RTU Easy
Master Error
End Flag
(CP1L EL-
type CPU
Units)
734
Function
ON while the serial port 1's commu-
nications settings are being changed
for a CP1L EM-type CPU Unit. This
flag will be turned ON when
STUP(237) is executed and it will be
turned OFF after the settings have
been changed.
ON while the serial port 2's commu-
nications settings are being changed
for a CP1L EM-type CPU Unit. This
flag will be turned ON when
STUP(237) is executed and it will be
turned OFF after the settings have
been changed.
ON while the serial port 1's commu-
nications settings are being changed
for a CP1L EL-type CPU Unit. This
flag will be turned ON when
STUP(237) is executed and it will be
turned OFF after the settings have
been changed.
Turn ON this bit to send a command
and receive a response for serial port 2
of a CP1L EM-type CPU Unit using the
Modbus-RTU easy master function.
Note This bit will be turned OFF
automatically by the system
when communications have
been completed.
Turn ON this bit to send a command
and receive a response for serial port
1 of a CP1L EL-type CPU Unit using
the Modbus-RTU easy master func-
tion.
Note This bit will be turned OFF
automatically by the system
when communications have
been completed.
ON when one command has been
sent and the response received for
serial port 2 of a CP1L EM-type CPU
Unit using the Modbus-RTU easy
master function.
ON when one command has been
sent and the response received for
serial port 1 of a CP1L EL-type CPU
Unit using the Modbus-RTU easy
master function.
ON when an error has occurred in
communications for serial port 2 of a
CP1L EM-type CPU Unit using the
Modbus-RTU easy master function.
The error code is output to D32252
in the DM fixed allocation words for
Modbus-RTU Easy Master.
ON when an error has occurred in
communications for serial port 1 of a
CP1L EL-type CPU Unit using the
Modbus-RTU easy master function.
The error code is output to D32252
in the DM fixed allocation words for
Modbus-RTU Easy Master.
Settings
Status
Status at
after
startup
mode
change
ON: Changing
Retained Cleared
OFF: Not
changing
ON: Changing
Retained Cleared
OFF: Not
changing
Turned ON:
Retained Cleared
Execution
started
ON: Execution
in progress.
OFF: Not exe-
cuted or execu-
tion completed.
ON: Execution
Retained Cleared
normal.
OFF: Execu-
tion error or still
in progress.
ON: Execution
Retained Cleared
error.
OFF: Execu-
tion normal or
still in progress.
Appendix D
Write
Related
timing
Flags,
Settings
---
---
---
---
---
DM fixed
allocation
words for
Modbus-
RTU Easy
Master:
D32300 to
D32399
---
---