Program Protection
Note
Prohibiting Creating
Program Files in File
Memory
1,2,3...
Note
446
(1) Copying the program is possible if read protection is not set.
(2) The setting to prohibit backing up the program is not effective until the
program is transferred to the PLC. Always transfer the program after
changing the setting.
When a password is set for the entire user program or for a task from the CX-
Programmer, prohibiting creating a program file (.OBJ) as a backup can be
set as an option. Doing so will make it impossible to create a program file in
file memory using the file memory operations. (This setting will also prohibit
uploading PLC data to the CX-Programmer and saving PLC data to a storage
device.)
CX-Programmer
When a password is set for the entire user program, or for one or more tasks,
Password?
backing up the user program (i.e., creating an OBJ program file) can be prohibited.
Creating a program file as a backup using online
operations can be prohibited.
CPU Unit
SYSMAC
CP1L
COM
01
03
05
07
09
11
01
03
05
07
09
11
NC
00
02
04
06
08
10
00
02
04
06
08
10
POWER
RUN
ERR/ALM
INH
LNK/ACT
BKUP
1
2
00
01
02
03
04
06
00
01
03
04
06
ANALOG INPUT
COM(V+)
COM
05
07
COM
02
COM
05
07
V1+ V2+ COM
MAC Address:
01234567890A
A program file (.OBJ) cannot be created with file memory operations.
Operating Procedure
1. When registering a password in the UM read protection password Box or
Task read protection Box, select the Prohibit from saving to a memory
card, and transferring program from PLC Option.
Properties
2. Go online and then either select PLC - Transfer - To PLC to transfer the
program or select PLC - Protection - Set Password and click the OK but-
ton.
Application
The above procedure enables using a password to protect against disclosure
of the program to unauthorized persons.
(1) Copying the program is possible if read protection is not set.
(2) The setting to prohibit backing up the program is not effective until the
program is transferred to the PLC. Always transfer the program after
changing the setting.
CX-Programmer
Memory Cassette
Section 8-7
No PLC data
can be uploaded.