B.10 o: Operator-Related Settings
B.10 o: Operator-Related Settings
The o parameters set up the HOA keypad displays.
u

o1: HOA Keypad Display Selection

No.
(Addr.
Name
Hex)
o1-01
Drive Mode Unit
(500)
Monitor Selection
o1-02
User Monitor Selection
(501)
after Power Up
o1-03
HOA Keypad Display
(502)
Selection
o1-06
User Monitor Selection
(517)
Mode
o1-07
Second Line Monitor
(518)
Selection
o1-08
Third Line Monitor
(519)
Selection
o1-09
Frequency Reference
(51C)
Display Units
o1-10
User-Set Display Units
(520)
Maximum Value
o1-11
User-Set Display Units
(521)
Decimal Display
Frequency Reference
o1-13
and Frequency Related
(3105)
Monitor Custom Units 1
Frequency Reference
o1-14
and Frequency Related
(3106)
Monitor Custom Units 2
306
LCD Display
Selects the content of the last monitor that is shown when
scrolling through Drive Mode display. Enter the last three digits
User Monitor Sel
of the monitor parameter number to be displayed: Uo-oo.
Power-On Monitor
1: Frequency reference (U1-01)
1: Frequency Ref
2: Direction
2: FWD/REV
3: Output frequency (U1-02)
3: Output Freq
4: Output current (U1-03)
4: Output Current
5: User Monitor
5: User Monitor
Sets the units the drive should use to display the frequency
Display Unit Sel
reference and motor speed monitors.
0: 0.01 Hz
0: 0.01 Hz
1: 0.01%
1: 0.01% (100% = E1-04)
2: r/min
2: r/min (calculated using the number of motor poles setting in
3: User Units
E2-04, E4-04, or E5-04)
3: User-selected units (set by o1-10 and o1-11)
0: 3 Monitor Sequential
Monitor Mode Sel
(Displays the next two sequential monitors)
0: 3 Mon Sequential
1: 3 Monitor Selectable (o1-07 and o1-08 selected monitor are
1: 3 Mon Selectable
shown)
Selects the monitor that is shown in the second line.
Enter the last three digits of the monitor parameter number to
2nd Monitor Sel
be displayed: Uo-oo. For example, set "403" to display
monitor parameter U4-03.
Selects the monitor that is shown in the third line.
Enter the last three digits of the monitor parameter number to
3rd Monitor Sel
be displayed: Uo-oo. For example, set "403" to display
monitor parameter U4-03.
Sets unit display for the frequency reference parameters and
Fref Disp Unit
frequency related monitors when o1-03 = 3.
0: WC
0: WC (Inch of water)
1: PSI
1: PSI (Pounds per square inch)
2: GPM
2: GPM (Gallons per minute)
3: °F
3: F (Degrees Fahrenheit)
4: CFM
4: CFM (Cubic feet per minute)
5: CMH
5: CMH (Cubic meters per hour)
6: LPH
6: LPH (Liters per hour)
7: LPS
7: LPS (Liters per second)
8: Bar
8: Bar (Bar)
9: Pa
9: Pa (Pascal)
10: °C
10: C (Degrees Celsius)
11: Mtr
11: Mtr (Meters)
12: Ft
12: Ft (Feet)
13: LPM
13: LPM (Liters per minute)
14: CMM
14: CMM (Cubic meters per minute)
15: Custom unit
15: Custom units (Determined by o1-12)
16: No Unit
16: None
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output
UserDisp Scaling
frequency.
o1-11 sets the position of the decimal position.
UserDisp Dec
Sets the customer-specified unit display for the frequency
Fref Cust Unit 1
reference parameters and frequency related monitors when
o1-03 = 3 and o1-09 = 15 as custom units.
Sets the customer-specified unit display for the frequency
Fref Cust Unit 2
reference parameters and frequency related monitors when
o1-03 = 3 and o1-09 = 15 as custom units
Description
YASKAWA TOEP YAIZ1U 03B YASKAWA AC Drive – Z1000 User Manual
Values
Page
Default: 106
Range: 104 to
181
699
Default: 1
181
Range: 1 to 5
Default: 0
182
Range: 0 to 3
Default: 0
182
Range: 0, 1
Default: 102
Range: 101 to
182
699
Default: 103
Range: 101 to
182
699
Default: 16
182
Range: 0 to 16
<1>
Default:
183
Range: 1 to
60000
<1>
Default:
183
Range: 0 to 3
Default: 41
183
Range: 30 to 7A
Default: 41
183
Range: 30 to 7A