4.8 Auto-Tuning
n
T2-03: PM Motor Type
Selects the type of PM motor the drive will operate.
No.
T2-03
Setting 0: IPM motor
Setting 1: SPM motor
n
T2-04: PM Motor Rated Power
Specifies the motor rated power in kilowatts.
No.
T2-04
n
T2-05: PM Motor Rated Voltage
Sets the motor rated voltage.
No.
T2-05
n
T2-06: PM Motor Rated Current
Enter the motor rated current in amps.
No.
T2-06
n
T2-07: PM Motor Base Frequency
Enter the motor base frequency in Hz.
Note:
T2-07 will be displayed when in OLV/PM.
No.
T2-07
n
T2-08: Number of PM Motor Poles
Enter the number of motor poles.
No.
T2-08
n
T2-10: PM Motor Stator Resistance
Enter the motor stator resistance per motor phase.
No.
T2-10
n
T2-11: PM Motor d-Axis Inductance
Enter the d-Axis inductance per motor phase.
No.
T2-11
142
Name
PM Motor Type
Name
PM Motor Rated Power
Name
PM Motor Rated Voltage
Name
PM Motor Rated Current
Name
PM Motor Base Frequency
Name
Number of PM Motor Poles
Name
PM Motor Stator Resistance
Name
PM Motor d-Axis Inductance
Setting Range
0, 1
Setting Range
0.00 to 650.00 kW
Setting Range
0.0 to 733.1 V
Setting Range
0.0% to 300.0% of the
drive rated current.
Setting Range
0.0 to 240.0 Hz
Setting Range
2 to 48
Setting Range
0.000 to 65.000 Ω
Setting Range
0.00 to 600.00 mH
YASKAWA TOEP YAIZ1U 03B YASKAWA AC Drive – Z1000 User Manual
Default
1
Default
Determined by o2-04
and C6-01
Default
575.0 V
Default
Determined by o2-04
Default
87.5 Hz
Default
6
Default
Determined by T2-02
Default
Determined by T2-02