H4: Analog Outputs - YASKAWA Z1000 User Manual

Ac drive for hvac fan and pump
Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

B.7 H Parameters: Multi-Function Terminals
H3-oo
Function
Setting
4
Output voltage bias
5
Accel/decel time gain
DC Injection Braking
6
current
Overtorque/undertorque
7
detection level
Stall Prevention level
8
during run
Output frequency lower
9
limit level
B
PI feedback
C
PI setpoint
D
Frequency bias
Motor temperature (PTC
E
input)
F
Through mode
16
Differential PI feedback PI Feedback 2
25
Secondary PI Setpoint
26
Secondary PI Feedback PI2 Feedback
u

H4: Analog Outputs

No.
(Addr.
Name
Hex)
Multi-Function Analog
H4-01
Output Terminal FM
(41D)
Monitor Selection
H4-02
Multi-Function Analog
(41E)
Output Terminal FM
Gain
H4-03
Multi-Function Analog
(41F)
Output Terminal FM
Bias
Multi-Function Analog
H4-04
Output Terminal AM
(420)
Monitor Selection
H4-05
Multi-Function Analog
(421)
Output Terminal AM
Gain
H4-06
Multi-Function Analog
(422)
Output Terminal AM
Bias
Multi-Function Analog
H4-07
Output Terminal FM
(423)
Signal Level Selection
Multi-Function Analog
H4-08
Output Terminal AM
(424)
Signal Level Selection
296
H3 Multi-Function Analog Input Settings
LCD Display
Voltage Bias
10 V = E1-05 (motor rated voltage)
Acc/Dec Change
10 V = 100%
10 V = Drive rated current
DC Brake Current
10 V = Drive rated current (V/f)
Torque Det Level
10 V = Motor rated torque (OLV/PM)
10 V = Drive rated current
Stall Prev Level
10 V = E1-04 (maximum output frequency)
Ref Lower Limit
PI Feedback1
10 V = 100%
PI Set Point
10 V = 100%
Freq Ref Bias 2
10 V = E1-04 (maximum output frequency)
10 V = 100%
Motor PTC
Not Used
Set this value when using the terminal in the pass-through mode.
10 V = 100%
PI2 Setpoint
10 V = S3-02 (maximum output frequency)
10 V = S3-02 (maximum output frequency)
LCD Display
Selects the data to be output through multi-function analog
output terminal FM.
Term FM FuncSel
Set the desired monitor parameter to the digits available in
Uo-oo.
For example, enter "103" for U1-03.
Sets the signal level at terminal FM that is equal to 100% of the
selected monitor value.
Terminal FM Gain
Sets the signal level at terminal FM that is equal to 0% of the
selected monitor value.
Terminal FM Bias
Selects the data to be output through multi-function analog
output terminal AM.
Set the desired monitor parameter to the digits available in
Terminal AM Sel
Uo-oo.
For example, enter "103" for U1-03.
Sets the signal level at terminal AM that is equal to 100% of
the selected monitor value.
Terminal AM Gain
Sets the signal level at terminal AM that is equal to 0% of the
selected monitor value.
Terminal AM Bias
Level Select1
0: 0 to 10 V
0: 0 to 10 Vdc
1: -10 V to 10 V
1: -10 to 10 Vdc
2: 4 to 20 mA
2: 4-20 mA
AO Level Select2
0: 0 to 10 V
0: 0 to 10 Vdc
1: -10 V to 10 V
1: -10 to 10 Vdc
2: 4 to 20 mA
2: 4 to 20 mA
Description
Description
YASKAWA TOEP YAIZ1U 03B YASKAWA AC Drive – Z1000 User Manual
Page
171
171
171
Values
Page
Default: 102
Range: 000 to
655
Default: 100.0%
Min.: -999.9
Max.: 999.9
Default: 0.0%
Min.: -999.9
Max.: 999.9
Default: 103
Range: 000 to
655
Default: 50.0%
Min.: -999.9
Max.: 999.9
Default: 0.0%
Min.: -999.9
Max.: 999.9
Default: 0
Range: 0 to 2
Default: 0
Range: 0 to 2

Advertisement

Table of Contents
loading

Table of Contents