B3: Speed Search - YASKAWA Z1000 User Manual

Ac drive for hvac fan and pump
Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

No.
(Addr.
Name
Hex)
b2-12
Short Circuit Brake
(1BA)
Time at Start
b2-13
Short Circuit Brake
(1BB)
Time at Stop
b2-18
Short Circuit Braking
(177)
Current
<1> Default setting is determined by parameter A1-02, Control Method Selection.
u

b3: Speed Search

No.
(Addr
Name
Hex.)
b3-01
Speed Search Selection
(191)
at Start
b3-02
Speed Search
(192)
Deactivation Current
b3-03
Speed Search
(193)
Deceleration Time
b3-04
V/f Gain during Speed
(194)
Search
b3-05
Speed Search Delay
(195)
Time
b3-06
Output Current 1 during
(196)
Speed Search
Current Control Gain
b3-08
during Speed Search
(198)
(Speed Estimation
Type)
b3-10
Speed Search Detection
(19A)
Compensation Gain
b3-14
Bi-Directional Speed
(19E)
Search Selection
b3-17
Speed Search Restart
(1F0)
Current Level
b3-18
Speed Search Restart
(1F1)
Detection Time
b3-19
Number of Speed
(1F2)
Search Restarts
b3-24
Speed Search Method
(1C0)
Selection
b3-25
Speed Search Wait Time SpdSrch WaitTime
(1C8)
YASKAWA TOEP YAIZ1U 03B YASKAWA AC Drive – Z1000 User Manual
LCD Display
OLV/PM
OLV/PM
SC Brake T@Start
Sets the time for Short Circuit Braking operation at start.
OLV/PM
OLV/PM
SC Brake T@Stop
Sets the Short Circuit Braking operation time at stop.
OLV/PM
OLV/PM
Shrt Cir Brk
Determines the current level for Short Circuit Braking. Set as a
percentage of the motor rated current.
LCD Display
SpdSrch at Start
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Sets the current level at which the speed is assumed to be
detected and Speed Search is ended. Set as a percentage of the
SpdSrch DeactCur
drive rated current.
Sets output frequency reduction time during Speed Search.
SpdSrch Dec Time
Determines how much to lower the V/f ratio during Speed
Search.
SpdSrch V/f
Output voltage during Speed Search equals the V/f setting
multiplied by b3-04.
When using an external contactor on the output side, b3-05
Search Delay
delays executing Speed Search after a momentary power loss to
allow time for the contactor to close.
Sets the current injected to the motor at the beginning of Speed
Estimation Speed Search. Set as a coefficient for the motor rated
Srch Im Lvl1
current.
Sets the proportional gain for the current controller during
Speed Search.
Srch ACR P Gain
Sets the gain which is applied to the speed detected by Speed
Estimation Speed Search before the motor is reaccelerated.
Srch Detect Comp
Increase this setting if ov occurs when performing Speed Search
after a relatively long period of baseblock.
Bidir Search Sel
0: Disabled (uses the direction of the frequency reference)
0: Disabled
1: Enabled (drive detects which way the motor is rotating)
1: Enabled
Sets the Speed Search restart current level as a percentage of the
SrchRestart Lvl
drive rated current.
Sets the time to detect Speed Search restart.
SrchRestart Time
Sets the number of times the drive can attempt to restart when
Num of SrchRestr
performing Speed Search.
SpdSrch Method
0: Current Detection
0: CurrentDetection
1: Speed Estimation
1: Speed Estimation
Sets the time the drive must wait between each Speed Search
restart attempt.
Description
Description
B.2 b: Application
Values
Page
Default: 0.00 s
Min.: 0.00
Max.: 25.50
Default: 0.50 s
Min.: 0.00
Max.: 25.50
Default: 100.0%
Min.: 0.0
Max.: 200.0
Values
Page
<1>
Default:
154
Range: 0, 1
<1>
Default:
154
Min.: 0%
Max.: 200%
Default: 2.0 s
Min.: 0.1
154
Max.: 10.0
<2>
Default:
154
Min.: 10%
Max.: 100%
Default: 0.2 s
Min.: 0.0
Max.: 100.0
<2>
Default:
155
Min.: 0.0
Max.: 2.0
<1> <2>
Default:
Min.: 0.00
Max.: 6.00
Default: 1.05
Min.: 1.00
155
Max.: 1.20
<1>
Default:
155
Range: 0, 1
Default: 150%
Min.: 0
155
Max.: 200
Default: 0.10 s
Min.: 0.00
155
Max.: 1.00
Default: 3
Min.: 0
155
Max.: 10
B
Default: 0
156
Range: 0, 1
Default: 0.5 s
Min.: 0.0
156
Max.: 300.0