3.8 Main Circuit Wiring
Drive Model
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
⊖, ⊕1, ⊕2
5A0017
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
⊖, ⊕1, ⊕2
5A0022
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
5A0027
⊖, ⊕1, ⊕2
5A0032
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
⊖, ⊕1
5A0041
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
⊖, ⊕1
5A0052
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
⊖, ⊕1
5A0062
⊕3
82
Recomm. Gauge
Terminal
mm
Wire Range
2
2
(AWG, kcmil)
mm
(AWG, kcmil)
6.0
6.0 to 16
(10)
(10 to 6)
6.0
6.0 to 16
(10)
(10 to 6)
6.0 to 16
–
(10 to 6)
6.0 to 10
–
(10 to 8)
10
6.0 to 10
(8)
(12 to 8)
10
6.0 to 16
(8)
(10 to 6)
6.0
6.0 to 16
(10)
(10 to 6)
6.0 to 16
–
(10 to 6)
6.0 to 10
–
(10 to 8)
10
6.0 to 10
(8)
(10 to 6)
16
16 to 25
(6)
(6 to 4)
16
16 to 25
(6)
(6 to 4)
16 to 25
–
(6 to 4)
6.0 to 10
–
(10 to 8)
16
10 to 16
(6)
(10 to 6)
16
6.0 to 25
(6)
(10 to 3)
16
6.0 to 25
(6)
(10 to 3)
–
(6 to 1)
4.0 to 25
–
(12 to 3)
16
10 to 16
(6)
25
6.0 to 25
(4)
(10 to 3)
16
6.0 to 25
(6)
(10 to 3)
16 to 35
–
(6 to 1)
10 to 25
–
(8 to 3)
16
10 to 16
(6)
25
6.0 to 95
(4)
(10 to 4/0)
25
6.0 to 95
(4)
(10 to 4/0)
25 to 95
–
(4 to 4/0)
16 to 95
–
(6 to 4/0)
25
(4)
YASKAWA TOEP YAIZ1U 03B YASKAWA AC Drive – Z1000 User Manual
Screw
Size
M5
M6
M5
M6
M6
M5
M6
M8
(6)
M8
(6)
M10
25
(4)
Tightening Torque
N·m (lb.in.)
3.6 to 4.0
(31.8 to 35.4)
2.7 to 3.0
(23.9 to 26.6)
5.4 to 6.0
(47.8 to 53.1)
3.6 to 4.0
(31.8 to 35.4)
2.7 to 3.0
(23.9 to 26.6)
5.4 to 6.0
(47.8 to 53.1)
5.4 to 6.0
(47.8 to 53.1)
2.7 to 3.0
(23.9 to 26.6)
5.4 to 6.0
(47.8 to 53.1)
9.0 to 11
(79.7 to 97.4)
9.0 to 11
(79.7 to 97.4)
18 to 23
(159 to 204)