YASKAWA Z1000 User Manual page 287

Ac drive for hvac fan and pump
Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

No.
(Addr.
Name
Hex)
F7-09
(3ED)
Gateway Address 1
<6>
F7-10
(3EE)
Gateway Address 2
<6>
F7-11
(3EF)
Gateway Address 3
<6>
F7-12
(3E0)
Gateway Address 4
<6>
F7-13
Address Mode at Startup
(3F1)
F7-14
Duplex Mode Selection
(3F2)
F7-15
Communication Speed
(3F3)
Selection
<7>
F7-16
Communication Loss
(3F4)
Timeout
F7-17
EtherNet/IP Speed
(3F5)
Scaling Factor
F7-18
EtherNet/IP Current
(3F6)
Scaling Factor
F7-19
EtherNet/IP Torque
(3F7)
Scaling Factor
F7-20
EtherNet/IP Power
(3F8)
Scaling Factor
F7-21
EtherNet/IP Voltage
(3F9)
Scaling Factor
F7-22
EtherNet/IP Time
(3FA)
Scaling
F7-23 to
F7-32
Dynamic Output
(3FB to
Assembly Parameters
374)
F7-33 to
F7-42
Dynamic Input
(375 to
Assembly Parameters
37E)
<1> When using this setting, be sure to take safety measures, such as installing an emergency stop switch. The drive will continue to operate when a
fault is detected.
<3> Parameter setting value is not reset to the default value when the drive is initialized.
<4> Cycle power for setting changes to take effect.
YASKAWA TOEP YAIZ1U 03B YASKAWA AC Drive – Z1000 User Manual
LCD Display
Gateway IP Add 1
Sets the most significant octet of network Gateway address.
Sets the second most significant octet of network Gateway
Gateway IP Add 2
address.
Sets the third most significant octet of network Gateway
Gateway IP Add 3
address.
Sets the fourth most significant octet of network Gateway
Gateway IP Add 4
address.
Select the option address setting method
IP Add Mode Sel
0: User Defined
0: Static
1: BOOTP
1: BOOTP
2: DHCP
2: DHCP
Selects duplex mode setting.
Duplex Select
0: Half Duplex
0: Half duplex forced
1: Auto Negotiate
1: Auto-negotiate duplex mode and communication speed
2: Full Duplex
2: Full duplex forced
Baud Rate
Sets the communication speed
10: 10 Mbps
10: 10 Mbps
100: 100 Mbps
100: 100 Mbps
Sets the timeout value in 0.1 s for communication loss
detection.
CommLoss Tout
Example: Setting this parameter to 100 represents 10.0 seconds.
Setting this parameter to 0 disables the connection timeout.
Sets the scaling factor for the speed monitor in EtherNet/IP
EN Speed Scale
Class ID 2AH Object.
Sets the scaling factor for the output current monitor in
EN Current Scale
EtherNet/IP Class ID 2AH Object.
Sets the scaling factor for the torque monitor in EtherNet/IP
EN Torque Scale
Class ID 2AH Object.
Sets the scaling factor for the power monitor in EtherNet/IP
EN Power Scale
Class ID 2AH Object.
Sets the scaling factor for the voltage monitor in EtherNet/IP
EN Voltage Scale
Class ID 2AH Object.
Sets the scaling factor for the time monitor in EtherNet/IP Class
EN Time Scale
ID 2AH Object.
Parameters used in Output Assembly 116.
Each parameter contains a MEMOBUS/Modbus address. The
value received for Output Assembly 116 will be written to the
corresponding MEMOBUS/Modbus address.
A MEMOBUS/Modbus address value of 0 means the value
received for Output Assembly 116 will not be written to any
register.
Parameters used in Input Assembly 166.
Each parameter contains a MEMOBUS/Modbus address. The
value sent for Input Assembly 166 will be read from the
corresponding MEMOBUS/Modbus address.
A MEMOBUS/Modbus address value of 0 means the value sent
for Input Assembly 166 is not defined, and the default register
value will be returned.
B.6 F: Communication Option Parameters
Description
<5> <6>
<7>
<7>
Values
Page
Default: 192
Min.: 0
Max.: 255
Default: 168
Min.: 0
Max.: 255
Default: 1
Min.: 0
Max.: 255
Default: 1
Min.: 0
Max.: 255
Default: 2
Range: 0 to 2
Default: 1
Range: 0 to 2
Default: 10
Range: 10, 100
Default: 0
Min.: 0
Max.: 300
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Default: 0
B
287