Operation Parameters 2 [Bfm #14002, Bfm #14202] - Mitsubishi FX3U-20SSC-H User Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U

11.1.2 Operation parameters 2 [BFM #14002, BFM #14202]

BFM Number
X-axis
Y-axis
BFM #14002
BFM #14202
206
Bit
Number
Enables or disables the servo end check function.
b0
1: Enable
At an in-position signal, is determined the positioning operation
completion
0: Disable
Enables or disables the servo ready check function.
b1
1: Enable
Checks the ready signal ON/OFF at operation start / while operation
0: Disable
Enables or disables the OPR interlock function.
1: Enable
b2
D isab le s the S TART com ma nd w ith out zero r etur n com ple tio n
Enables the START command with zero return completion (zero return
completed: ON)
0: Disable
Enables or disables the ring counter setting. (Ver.1.10 or later)
b3
1: Enables the ring operation.
0: Disables the ring operation.
Set the stop method when the Stop command turns ON
(Ver.1.20 or later)
→ For details on sudden stop / Normal deceleration stop,
b4
1: Sudden stop
0: Normal deceleration stop
Set the stop method when the software limit turns ON
(Ver.1.20 or later)
→ For details on sudden stop / Normal deceleration stop,
b5
1: Sudden stop
0: Normal deceleration stop
Set the stop method when the PLC limit turns ON
(Ver.1.20 or later)
→ For details on sudden stop / Normal deceleration stop,
b6
1: Sudden stop
0: Normal deceleration stop
Set the stop method when the Servo amplifier stroke limit turns ON
(Ver.1.20 or later)
→ For details on sudden stop / Normal deceleration stop,
b7
1: Sudden stop
0: Normal deceleration stop
Set the servo ON/OFF status to be selected when the servo amplifier is started
up (in Ver. 1.30 or later).
*1
1: Servo OFF
The servo OFF status is selected when the servo amplifier is started up. It
is necessary to specify the servo ON status in a sequence program.
→ For details of the servo ON/OFF status selection at startup,
b8
0: Servo ON
The servo ON status is automatically selected when the servo amplifier is
started up.
(The servo amplifier operates in the same way as versions earlier than
Ver. 1.30.)
b9 to b13
Not available
11 Buffer Memory (Parameters & Monitored Data)
11.1 Positioning Parameters
Description
→ For details on the servo end check,
refer to Subsection 7.9.2
→ For details on the servo ready check,
refer to Subsection 7.9.1
→ For details on the OPR interlock,
refer to Subsection 7.9.10
→ For details on the ring couter setting,
refer to Section 7.8
refer to Section 7.5
refer to Section 7.5
refer to Section 7.5
refer to Section 7.5
refer to Subsection 7.9.6
Default
H0007

Advertisement

Table of Contents
loading

Table of Contents