Mitsubishi FX3U-20SSC-H User Manual page 199

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
Operation information
Operation
Name
target axis
Circular
interpolation
XY-axis
(radius,
CW direction)
Circular
interpolation
XY-axis
(radius,
CCW direction)
X-axis
Y-axis
Mechanical zero
return operation
XY-axis
X-axis
Changes the
Y-axis
current address
XY-axis
Absolute address
-
Relative address
-
Dwell
-
Jump
-
Setting target
table
information
Setting
X-
Y-
Symbol
value
axis
axis
CW_r
23
-
-
CCW_r
24
-
-
DRVZ_X
25
-
DRVZ_Y
26
-
DRVZ_XY
27
-
-
SET_X
90
-
SET_Y
91
-
SET_XY
92
-
-
ABS
93
INC
94
-
-
TIM
95
-
-
-
-
JMP
96
-
-
Other setting items
Position
Speed
information
information
XY-
x
y
fx/f
fy
axis
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
10 Table Operation
10.1 Outline of Table Operation
Circle
information
Remarks
m code
information
i/r
j
For the
-
positioning
operation details,
refer to
Subsection
-
9.11.2.
-
-
For the
positioning
-
-
operation details,
refer to Section
-
-
8.1.
-
-
Changes the
current address
-
-
(user). Refer to
-
-
Subsection 7.9.9.
When this
command is
issued, the
position
information (x, y)
of the table
operation
-
-
becomes an
absolute address,
which specifies
positions from the
(0, 0) point.
(absolute address
is specified by
default)
When this
command is
issued, the
position
information (x, y)
-
-
of the table
operation
becomes a
relative address
based on the
current address.
-
-
The 20SSC-H
waits for the
-
-
specified time
period. Use this to
specify waiting
-
-
time for shifting
operations.
-
-
-
Jumps to the
specified table
-
-
-
number.
Jumping from an
X-axis table to a
-
-
-
Yaxis table is not
allowed.
1
2
3
4
5
6
7
8
9
10
193

Advertisement

Table of Contents
loading

Table of Contents