Monitor Data

Operating conditions for the positioning system are stored as monitor data. The following buffer memories for
monitor data are read-only memories except for the current address (user) [BFM #1, #0 (X-axis), BFM #101,
#100 (Y-axis)].
For X-axis: BFM #0 to #99
For Y-axis: BFM #100 to #199
Caution
Do not use unlisted BFMs for changing values not described in this section.

11.3.1 Current address (User) [BFM #1, #0, BFM #101, #100]

The current address data is stored in units specified by the user
BFM Number
X-axis
BFM
BFM #1,#0
#101,#100
*1.
Refer to the section shown below for details on the user units.
POINT
• The stored address data is always handled as an absolute address.
• The unit of the value is a user-specified one and includes a magnification setting for position data.
The unit and magnification setting can be specified by the operation parameters 1.
• It is possible to change the current address of a stopped axis to any address.
Overwrite the current address (user) with a new address. The current address will be changed and its
pulse data will be updated.
Set a value within the range from 0 to the ring value during the ring operation.

11.3.2 Current address (Pulse) [BFM #3, #2, BFM #103, #102]

The current address is converted into pulses and stored.
BFM Number
X-axis
BFM
BFM #3,#2
#103,#102
POINT
• The stored address data is always handled as an absolute address (converted pulse data).
• It is possible to change the current address of a stopped axis to any address.
Overwrite the current address (user) with a new address. The current address will be changed and its
pulse data will be updated.
Set a value within the range from 0 to the ring value during the ring operation.
226
Y-axis
-2,147,483,648 to 2,147,483,647 (user unit)
→ For details on the operation parameters 1, refer to Subsection 11.1.1
→ For details on the current address change function, refer to Subsection 7.9.9
Y-axis
-2,147,483,648 to 2,147,483,647 PLS
→ For details on the converted pulse data, refer to Section 7.10
→ For details on the current address change function, refer to Subsection 7.9.9
11 Buffer Memory (Parameters & Monitored Data)
*1
.
Description
*1
Description
11.3 Monitor Data
Value Format
Default
Decimal
-
→ Refer to Section 7.10
Value Format
Default
Decimal
-