11.1.20 External input selection [BFM #14044, BFM #14244]

BFM Number
X-axis
Y-axis
BFM #14044
BFM #14244
11.1.21 Ring counter upper limit value
[BFM #14101, #14100, BFM #14301, #14300]
Sets the ring value to enable ring operation for the current address. (Ver.1.10 or later)
BFM Number
X-axis
Y-axis
BFM
BFM
#14101,
#14301,
#14100
#14300
*1.
For details on the user units, refer to the following.

11.1.22 Sudden stop deceleration time [BFM #14102, BFM #14302]

Set the time to reach 0 speed from the maximum speed at sudden stop. (Ver.1.20 or later)
BFM Number
X-axis
Y-axis
BFM #14102
BFM #14302
POINT
• The sudden stop deceleration time becomes 1 ms when set at 0 ms or less, and becomes 5000 ms when
set at 5001 ms or more.
Bit
Number
Sets the FLS, RLS signals from the servo amplifier to be used/not used
→For instructions on how to use forward/reverse rotation limit,
1: Use
b0
Use forward/reverse rotation limits from the servo amplifier and those from
the PLC.
0: Not use
Use only forward/reverse rotation limits from the PLC.
Sets the DOG signals from the servo amplifier to be used/not used
→For details on the mechanical zero return, refer to Section 8.1
1: Use
Use DOG signals from the servo amplifier.
b1
0: Not use
Use DOG signals from the 20SSC-H.
The "b12" in command parameter1 sets the 20SSC-H DOG signal.
b2 to b7
Not available
Sets the FLS/RLS signal logic of the servo motor
b8
1: NC-contact (servo amplifier)
0: NO-contact (servo amplifier)
Sets the DOG signal logic of the servo motor
b9
1: NC-contact (servo amplifier)
0: NO-contact (servo amplifier)
b10 to b15 Not available
Setting range : 1 to 359,999,999 (user unit)
Set the value within 1 to 359,999,999 PLS in the converted pulse data
→ For details on the sudden stop deceleration time, refer to Section 7.5
Setting range: 1 to 5000 ms
11 Buffer Memory (Parameters & Monitored Data)
11.1 Positioning Parameters
Description
refer to Section 7.3
→For details on the operation parameters 1,
refer to Subsection 11.1.1
Description
*1
*1
Description
Default
H0100
Default
K359,999
.
→ Refer to Section 7.10
Default
K200