Note
To transfer the following parameters from the buffer memory (BFM) to the servo amplifier, turn the servo
parameter transfer command (b9) of operation command 2 [BFM #519 (X-axis) and #619 (Y-axis)] to ON.
• Auto tuning mode
• Auto tuning response
• Feed forward gain
• Ratio of load inertia moment
to servo motor inertia moment
• Model control gain
6 Memory Configuration and Data Operation
→ For the operation command, refer to Subsection 11.4.11
→ For the operation procedure, refer to Subsection 7.1.8
• Position control gain
• Speed control gain
• Speed integral compensation
• Speed differential compensation
6.2 Data Transfer Process