FX
-20SSC-H Positioning Block User's Manual
3U
BFM Number
Servo
Amplifier
X-axis
Y-axis
Parameter No.
BFM
BFM
PC10
#15073
#15273
BFM
BFM
PC11
#15074
#15274
BFM
BFM
PC12
#15075
#15275
BFM
BFM
PC13
#15076
#15276
BFM
BFM
PC14
#15077
#15277
BFM
BFM
PC17
#15080
#15280
BFM
BFM
PC20
#15083
#15283
BFM
BFM
PC21
#15084
#15284
BFM
BFM
PC24
#15087
#15287
BFM
BFM
PC31
#15094
#15294
Name
Select a signal to be output to the analog monitor 2.
0
0
0: Servo motor speed (±8V at the maximum)
1: Torque (±8 V at the maximum)
2: Servo motor speed (+8V at the maximum)
3: Torque (+8 V at the maximum)
4: Current command (±8 V at the maximum)
5: Speed command (±8V at the maximum)
6: Droop pulses (±10 V/1 × 10
Analog monitor 2
7: Droop pulses (±10 V/1 × 10
output
8: Droop pulses (±10 V/1 × 10
9: Droop pulses (±10 V/1 × 10
A: Feedback position (±10 V/1 × 10
B: Feedback position (±10 V/1 × 10
C: Feedback position (±10 V/1 × 10
D: Bus voltage (+8 V / 400 V)
*A: Encoder pulse unit
*B: Outputs 8 V as the maximum torque
*C: Can be used for the absolute position detection system
Analog monitor 1
Set the offset voltage of the analog monitor 1 (MO1) output.
offset
Setting range: -999 to 999 mV
Analog monitor 2
Set the offset voltage of the analog monitor 2 (MO2) output.
offset
Setting range: -999 to 999 mV
Analog monitor
feedback position
Set the standard position of feedback output with analog monitor 1
output standard data
(MO1) or 2 (MO2).
Low
Setting range: -9999 to 9999 PLS
(Ver.1.40 or later)
Analog monitor
feedback position
Set the standard position of feedback output with analog monitor 1
output standard data
(MO1) or 2 (MO2).
High
Setting range: -9999 to 9999 (× 10000PLS)
(Ver.1.40 or later)
Select the home position setting condition in the absolute position
Function selection
detection system.
C-4
0: Need to pass motor Z-phase after power on
1: Not need to pass motor Z-phase after power on
Setting when undervoltage alarm occurs
0
0
Function selection
C-7
0: Waveform of power supply voltage is not distorted
(Ver.1.40 or later)
1: Set "1" if undervoltage alarm occurs because of distorted power
supply voltage waveform when using power regenerative converter
or power regeneration common converter
Used to clear the alarm history.
0
0
Alarm history clear
(Ver.1.40 or later)
0: Disable
1: Enable
Forced stop
Only the MR-J3- BS
deceleration time
Set deceleration time constant for forced stop deceleration.
constant
Setting range: 0 to H1FFF
(Ver.1.40 or later)
Vertical axis freefall
Only the MR-J3- BS
prevention
Set the compensation amount of the vertical axis freefall prevention
compensation
function.
amount
Setting range: HF63C to H09C4 REV
(Ver.1.40 or later)
11 Buffer Memory (Parameters & Monitored Data)
Description
0
Analog monitor 2 (MO2) output selection
*B
*B
2
*A
PLS)
3
*A
PLS)
4
*A
PLS)
5
*A
PLS)
6
*A*C
PLS)
7
*A*C
PLS)
8
*A*C
PLS)
0
Setting when undervoltage alarm occurs
0
Alarm history clear
11.2 Servo Parameters
11
Default
12
13
H0001
K0
K0
K0
K0
K1
H0000
H0000
H0000
H0000
223
A
B