3. Speed information
The actual operation speed (vector speed) is "X-axis operation speed 1 x X-axis override setting."
The operation speed 1 for the X-axis can be changed using the operation speed change function except
under the following conditions.
• During deceleration operation
• When the speed change disable during operation signal is ON.
4. Position (address) information
The absolute/relative address can be specified in the operation information.
With the specified absolute address: Specifies a target address (position) using address 0 as the base.
With the specified relative address:
5. Circle information (radius)
Set the radius of a circle with by r.
With specified positive (+) value: Operates the small circle (a) path.
With specified negative (-) value: Operates the big circle (b) path.
→ For change of the operation speed, refer to Section 7.6
Specifies a travel amount from the current address.