Changing Of Set Positioning Parameters (Number Of Pulses And Frequency - Mitsubishi MELSEC-F FX3U Series User Manual

Hide thumbs Also See for MELSEC-F FX3U Series:
Table of Contents

Advertisement

FX
/FX
Series PLC User's Manual - Positioning Control Edition
3U
3UC
Built-in Positioning Function
11.4.2

Changing of Set Positioning Parameters (Number of Pulses and Frequency)

"Pulses" and "frequency" set by positioning parameters in a positioning table will be stored in the devices
starting from the specified first device as shown below. The set "pulses" and "frequency" can be changed
using the display module or the indicator.
Caution:
If "positioning type" is set to "DPLSV (Variable Speed Pulse Output)", "frequency (Hz)" value set on the
screen will be stored as the set number of pulses, and the device for "frequency" will be "K0".
To use "pulses" and "frequency" changed by the display module or the indicator even after turning
off and then on the power again:
Enter a check.
11 Batch Data Positioning Mode (TBL Instruction)
11.4 Positioning Parameter Setting
If the Head Address is set to "R0":
Pulse
output
Number of
Positioning
destination
table No.
pulses
device
1
R1,R0
2
R5,R4
Y000
3
R9,R8
100
R397,R396
1
R401,R400
2
R405,R404
Y001
3
R409,R408
100
R797,R796
1
R801,R800
2
R805,R804
Y002
3
R809,R808
100
R1197,R1196 R1199,R1198
1
R1201,R1200 R1203,R1202
2
R1205,R1204
Y003
3
R1209,R1208
100
R1597,R1596
To use "pulses" and "frequency" changed by
the display module or the indicator even after
turning off and then on the power again, enter
a check in "Positioning table settings will not
be initialized when the PLC is powered on"
check box in "Positioning instruction Setting"
window of the positioning parameters. To use
this function, use the uninterruptible power
supply type devices.
If this function is not set, the data set by the
positioning parameters will be initialized.
A
B
Frequency
Apx.
R3,R2
R7,R6
R11,R10
R399,R398
R403,R402
R407,R406
R411,R410
R799,R798
R803,R802
R807,R806
R811,R810
R1207,R1206
R1211,R1210
R1599,R1598
B - 135