11.1.2 Operation parameters 2 [BFM #14002, BFM #14202]

BFM Number
X-axis
Y-axis
BFM #14002
BFM #14202
*1.
BFM # 14202 (b14) is not available.
120
Bit
Number
Enables or disables the servo end check function.
b0
1: Enable
At an in-position signal, is determined the positioning operation
completion
0: Disable
Enables or disables the servo ready check function.
b1
1: Enable
Checks the ready signal ON/OFF at operation start / while operation
0: Disable
Enables or disables the OPR interlock function.
→ For details on the OPR interlock, refer to Subsection 7.8.9
1: Enable
b2
D isab le s the S TART com ma nd w ith out zero r etur n com ple tio n
Enables the START command with zero return completion (zero return
completed: ON)
0: Disable
Enables or disables the ring counter setting. (Ver.1.10 or later)
b3
1: Enables the ring operation.
0: Disables the ring operation.
Set the stop method when the Stop command turns ON
(Ver.1.20 or later)
→ For details on sudden stop / Normal deceleration stop,
b4
1: Sudden stop
0: Normal deceleration stop
Set the stop method when the software limit turns ON
(Ver.1.20 or later)
→ For details on sudden stop / Normal deceleration stop,
b5
1: Sudden stop
0: Normal deceleration stop
Set the stop method when the PLC limit turns ON
(Ver.1.20 or later)
→ For details on sudden stop / Normal deceleration stop,
b6
1: Sudden stop
0: Normal deceleration stop
Set the stop method when the Servo amplifier limit turns ON
(Ver.1.20 or later)
→ For details on sudden stop / Normal deceleration stop,
b7
1: Sudden stop
0: Normal deceleration stop
b8 to b13
Not available
Sets the interpolation gear ratio selection (Ver.1.20 or later)
→ For details on interpolation gear ratio selection, refer to
*1
b14
1: X-axis, Y-axis
0: X-axis
Set the servo parameters transfer souce when the servo amplifier series is
selected. (Ver.1.10 or later)
b15
1: Transfers data stored in the buffer memory to the servo amplifier.
0: Transfers data stored in the flash memory to the servo amplifier.
11 Buffer Memory (Parameters & Monitored Data)
Description
→ For details on the servo end check, refer to
→ For details on the servo ready check, refer to
→ For details on the ring couter setting, refer to
For details on servo parameter transfer, refer to
11.1 Positioning Parameters
Default
Subsection 7.8.2
Subsection 7.8.1
Section 7.7
refer to Section 7.5
H0007
refer to Section 7.5
refer to Section 7.5
refer to Section 7.5
Subsection 7.10.3
Subsection 6.3.3