Current Manual Pulse Input Value; Input Frequency Of Manual Pulse Generator - Mitsubishi FX3U-20SSC-H User Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
8.3.2

Current manual pulse input value

The current number of total input pulses from the manual pulse generator is stored.
The current value is added in normal rotation, and subtracted in reverse rotation.
The stored data does not include the manual pulse generator input magnification.
Manual pulse generator input
current value
8.3.3

Input frequency of manual pulse generator

The frequency of the manual pulse generator inputs is stored.
The sign of an increasing count is positive (+), while the sign of a decreasing count is negative (-).
The stored data does not include the manual pulse generator input magnification.
Manual pulse generator input
frequency
150
BFM Number
X-axis
Y-axis
BFM #13, #12
BFM #113, #112
BFM Number
X-axis
Y-axis
BFM #15, #14
BFM #115, #114
8.3 Manual pulse generator operation
Data type
Monitor data
Data type
Monitor data
8 Manual Control

Advertisement

Table of Contents
loading

Table of Contents