11.4.7 Speed change value [BFM #513, #512, BFM #613, #612]

This data item sets the velocity change value.
BFM Number
X-axis
Y-axis
BFM
BFM
#513,#512
#613,#612
*1.
Refer to the section shown below for details on the user units.
*2.
-2,147,483,648 to 2,147,483,647 with Variable Speed operation.

11.4.8 Target position change value (Address) [BFM #515, #514, BFM #615, #614]

This data item sets the target address for the target address change function.
BFM Number
X-axis
Y-axis
BFM
BFM
#515,#514
#615,#614
*1.
Refer to the section shown below for details on the user units.

11.4.9 Target position change value (Speed) [BFM #517, #516, BFM #617, #616]

This data item sets the operation speed for the target address change function.
BFM Number
X-axis
Y-axis
BFM
BFM
#517,#516
#617,#616
*1.
Refer to the section shown below for details on the user units.

11.4.10 Operation command 1 [BFM #518, BFM #618]

BFM Number
Bit
Number
X-axis
Y-axis
b0
b1
BFM
BFM
b2
#518
#618
b3
b4
b5
→ For details on the operation speed change function, refer to Subsection 7.6.2
Setting range: 1 to 2,147,483,647 [User unit]
Set the value within 1 to 50,000,000 Hz in converted pulse data.
→ For details on the target address change function, refer to Subsection 7.6.3
Setting range: -2,147,483,648 to 2,147,483,647 [User unit]
Set the value within -2,147,483,648 to 2,147,483,647 PLS in the converted pulse data
→ For details on the target address change function, refer to Subsection 7.6.3
Setting range: 1 to 2,147,483,647 [User unit]
Set the value within 1 to 50,000,000 Hz in converted pulse data.
Setting Item
Set this to recover from errors and clear the following
information.
-
Error BFM numbers (BFM #6, BFM #106)
Error reset
-
Status information
Occurrence of an error (BFM #28 b5, BFM #128 b5)
-
Error code (BFM #29, BFM #129)
STOP command
When this bit is turned ON during positioning operation, operation
(deceleration
decelerates to stop.
→For details on the stop command, refer to Section 7.4
stop)
Set this to perform a deceleration stop while outputting pulses for
Forward rotation
forward rotation.
→For details on the forward rotation limit (LSF),
limit (LSF)
Set this to perform a deceleration stop while outputting pulses for
Reverse rotation
reverse rotation.
→For details on the reverse rotation limit (LSR),
limit (LSR)
Forward rotation
Pulses for forward rotation are output while this is set.
→For details on the JOG operations, refer to Section 8.2
JOG
Reverse rotation
Pulses for reverse rotation are output while this is set.
→For details on the JOG operations, refer to Section 8.2
JOG
11 Buffer Memory (Parameters & Monitored Data)
Description
*1 *2
Description
*1
Description
*1
Description
refer to Subsection 7.3.2
refer to Subsection 7.3.2
11.4 Control Data
Default
K1
→ Refer to Section 7.10
Default
K0
→ Refer to Section 7.10
Default
K1
→ Refer to Section 7.10
*1
Default
Detection
Edge
Level
H0000
Level
Level
Level
Level
239
11
12
13
A