FX
-20SSC-H Positioning Block User's Manual
3U
5.3
Input Wiring
An external power supply (24VDC) is necessary for the START, DOG, INT0, INT1 and S/S terminals.
5.3.1
Sink input wiring
Switch (sink type)
Manual pulse generator
(differential output type)
5.3.2
Source input wiring
Switch (source type)
Manual pulse generator
(differential output type)
32
Power supply of INT0, INT1,
24V DC
DOG, START
Interrupt input INT0
Interrupt input INT1
START command input
Near-point DOG input
Manual pulse generator input,
A-phase
A-phase
B-phase
Manual pulse generator input,
B-phase
Power supply of INT0, INT1,
24V DC
DOG, START
Interrupt input INT0
Interrupt input INT1
START command input
Near-point DOG input
Manual pulse generator input,
A-phase
A-phase
B-phase
Manual pulse generator input,
B-phase
20SSC-H
S/S
-INT0
-INT1
-START
-DOG
( A+)
- A+
( A-)
- A-
- B+
( B+)
- B-
( B-)
: "X" or "Y"
20SSC-H
S/S
-INT0
-INT1
-START
-DOG
( A+)
- A+
( A-)
- A-
- B+
( B+)
- B-
( B-)
: "X" or "Y"
5 Wiring