• Pulse generator magnification response (Ver.1.10 or later)
For the relationship between the response and input pulses/output pulses, refer to the figure below.
The response setting does not affect the output pulse frequency and pulse quantity.
MPG response
Manual pulse generator
Input pulses
(frequency, pulse quantity)
A-phase
B-phase
2-phase pulses
Frequency within 100kHz
Speed
Caution
An error may occur when the response is drastically changed from low to high or from high to low while the
manual pulse generator is operating.
148
BFM Number
X-axis
Y-axis
Sets the MPG response (Ver.1.10 or later)
The set value can be changed even during operation.
If the set value is smaller, the follow-up capability of output pulses to manual
pulse generator inputs is higher.
BFM #528
BFM #628
However, note that the machine may be overloaded if the speed is changed
drastically.
If the set value is larger, the follow-up capability of output pulses to manual
pulse generator inputs is lower, but the machine gives smoother motions
(outputs).
Manual pulse
generator input
magnification
Numerator
+
Denominator
-
*1. Set it in "MPG response" in the control data.
Description
20SSC-H
1
Deviation
counter
*1
Response
Manual pulse generator input
Output pulse when a small value is set in "MPG response"
Output pulse when a large value is set in "MPG response"
Time
8 Manual Control
8.3 Manual pulse generator operation
Servo
amplifier
Command
(output
AC Servo
pulses)
motor