Control Command Enable/Disable [Bfm #522]; Control Command [Bfm #523]; Table Operation Start Number [Bfm #521, Bfm #621] - Mitsubishi FX3U-20SSC-H User Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U

11.4.13 Table operation start number [BFM #521, BFM #621]

This data item sets a table information number for the table operation.
BFM Number
X-axis
BFM #521
BFM #621

11.4.14 Control command enable/disable [BFM #522]

This data item enables or disables control commands.
Once the model code is stored, control commands are enabled.
BFM Number
X-axis
BFM #522
Note
Write the model code (K5220) to the "control command enable/disable" before executing the system reset
command or control command.
After control commands are executed, "0" is automatically stored in the "control command enable/disable."

11.4.15 Control command [BFM #523]

This data item sets data to the buffer memory/the flash memory, or initializes the data.
BFM Number
Number
X-axis Y-axis
BFM #523
*1.
Timing of the detection
1) Level detection: activated when the bit is set or cleared.
2) Edge detection: activated at OFF-to-ON transition.
244
Y-axis
Setting range: 0 to 299
Y-axis
Model code (K5220)
Values other than the model code :disables control commands
Bit
Setting Item
b0
X-axis
Positioning
parameters save
command
b1
Y-axis
b2
X-axis
Table information
b3
Y-axis
save command
XY-
b4
axes
b5
X-axis
Servo parameters
save command
b6
Y-axis
b7
Not available
Positioning
b8
X-axis
parameters
initialization
b9
Y-axis
command
b10
X-axis
Table information
b11
initialization
Y-axis
command
XY-
b12
axes
b13
X-axis
Servo parameters
initialization
command
b14
Y-axis
b15
Not available
11 Buffer Memory (Parameters & Monitored Data)
→ For details on the table operation, refer to Chapter 10
Description
Description
:enables control commands
Description
Writes X-axis positioning parameters (BFM #14000 to
BFM #14199) into the flash memory.
Writes Y-axis positioning parameters (BFM #14200 to
BFM #14399) into the flash memory.
Writes X-axis table information (BFM #1000 to BFM
#3999) into the flash memory.
Writes Y-axis table information (BFM #4000 to BFM
#6999) into the flash memory.
Writes XY-axes table information (BFM #7000 to BFM
#12999) into the flash memory.
Writes X-axis servo parameters (BFM #15000 to BFM
#15199) into the flash memory.
Writes Y-axis servo parameters (BFM #15200 to BFM
#15399) into the flash memory.
-
Resets X-axis positioning parameters (BFM #14000 to
BFM #14199) to their factory default.
Resets Y-axis positioning parameters (BFM #14200 to
BFM #14399) to their factory default.
Resets X-axis table information (BFM #1000 to BFM
#3999) to their factory default.
Resets Y-axis table information (BFM #4000 to BFM
#6999) to their factory default.
Resets XY-axes table information (BFM #7000 to BFM
#12999) to their factory default.
Resets X-axis servo parameters (BFM #15000 to BFM
#15199) to their factory default.
Resets Y-axis servo parameters (BFM #15200 to BFM
#15399) to their factory default.
-
11.4 Control Data
Default
K0
Default
K0
*1
Default
Detection
Edge
-
H0000
Edge
-

Advertisement

Table of Contents
loading

Table of Contents