Mitsubishi FX3U-20SSC-H User Manual page 93

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
To cancel the remaining travel distance operation in the remaining
travel distance operation mode
When "remaining travel distance operation cancel command" is turned ON in standby status, the operation
for the remaining travel distance is cancelled and the positioning operation terminates.
Standby for remaining travel distance after stopped
Remaining travel distance operation cancel command
START command
STOP command
Standby for remaining travel
distance at stop
Remaining distance operation
cancel command
3. Wiring the stop switch
Connect the stop switch to the input terminal of the PLC.
For details of the PLC wiring method, refer to the following manual according to the PLC being used.
4. STOP command
Operate the PLC's STOP switch together with the 20SSC-H STOP command.
Speed
ON
START command
OFF
STOP command
Operation command 1 BFM #518 b9
Operation command 1 BFM #518 b1
Status information
Operation command 2 BFM #519 b0
7 Before Starting Positioning Operation
Remaining travel distance operation
(Canceled remaining travel distance)
ON
OFF
ON
OFF
ON
OFF
BFM Number
X-axis
Y-axis
BFM #618 b9
BFM #618 b1
BFM #28 b7
BFM #128 b7
BFM #619 b0
→ Refer to the FX
→ Refer to the FX
7.4 Handling the STOP command
Time
Data type
Control data
Control data
Monitor data
Control data
Hardware Edition
3U
Hardware Edition
3UC
87
1
2
3
4
5
6
7
8
9
10

Advertisement