Deceleration Time 2 [Bfm #14110, Bfm #14310] - Mitsubishi FX3U-20SSC-H User Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U

11.1.26 Deceleration time 2 [BFM #14110, BFM #14310]

This parameter sets the time for the operation speed to reach zero from the maximum speed.
The deceleration time except in sudden stop and interpolation operation consists of two types, "deceleration
time" and "deceleration time 2."
Use the acceleration/deceleration time change command in operation command 2 to select which type should
be used for actual positioning operation (Ver. 1.30 or later).
BFM Number
X-axis
Y-axis
BFM #14110
BFM #14310
Note
• The set value smaller than "0 ms" is handled as "1 ms", and the set value larger than "5001 ms" is handled
as "5000 ms."
• When using approximate S-shaped acceleration/deceleration, set a value within the range from 64 to 5000
ms (not less than 64 ms).
→ For setting of the deceleration time, refer to Subsection 11.1.9
→ For changeover of the acceleration/deceleration time, refer to Section 7.7
Setting range: 1 to 5000 ms
11 Buffer Memory (Parameters & Monitored Data)
11.1 Positioning Parameters
→ For the deceleration time, refer to Section 7.2
Description
11
12
Default
13
K200
A
B
215