Mitsubishi FX3U-20SSC-H User Manual page 182

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
2. Operation speed
The actual operation speed (vector speed) is "X-axis operation speed 1 x X-axis override setting."
Operation speed 1 for the X-axis can be changed using the operation speed change function except under
the following conditions.
• During deceleration operation
• When the speed change disable during operation signal is ON.
3. Address specification
The absolute/relative address can be specified.
With the specified absolute address: Specifies a target address (position) using address 0 as the base.
With the specified relative address: Specifies a travel amount from the current address.
4. Rotation Direction
With the specified absolute address: The rotation direction depends on whether the target address 1 is
With the specified relative address: The rotation direction is decided by the sign (positive/negative) of target
176
→ For change of the operation speed, refer to Section 7.6
larger or smaller than the current address.
address 1.
9 Positioning Control
9.9 Linear Interpolation Operation