11.1.2 Operation parameters 2 [BFM #14002, BFM #14202]
BFM Number
X-axis
Y-axis
BFM #14002
BFM #14202
11.1.3 Pulse rate [BFM #14005, #14004, BFM #14205, #14204]
This parameter sets the number of pulses to rotate servo motors once. "Mechanical system units" and
"Composite system units" require this setting, "Motor system units" ignores it.
BFM Number
X-axis
BFM
BFM
#14005,
#14205,
#14004
#14204
11.1.4 Feed rate [BFM #14007, #14006, BFM #14207, #14206]
This parameter sets the travel distance per revolution of the motor. "Mechanical system units" and
"Composite system units" require this setting, "Motor system units" ignores it.
BFM Number
X-axis
BFM
BFM
#14007,
#14207,
#14006
#14206
106
Bit
Number
Enables or disables the servo end check function.
b0
1: Enable
At an in-position signal, determinates the positioning operation completion
0: Disable
Enables or disables the servo ready check function.
b1
1: Enable
Checks the ready signal ON/OFF at operation start / while operation
0: Disable
Enables or disables the OPR interlock function.
1: Enable
Disables the START command without zero return completion
b2
Enables the START command with zero return completion (zero return
completed: ON)
0: Disable
b3 to b15
Not available
Y-axis
Setting range: 1 to 200,000,000 PLS/REV
Y-axis
Setting range: 1 to 200,000,000 (µm/REV, 10
11 Buffer Memory (Parameters & Monitored Data)
Description
→For details on the servo end check, refer to Subsection 7.5.2.
→For details on the servo ready check, refer to Subsection 7.5.1.
→ For details on the system of units, refer to Section 7.7
Description
→ For details on the system of units, refer to Section 7.7
Description
-4
inch/REV, mdeg/REV)
11.1 Positioning Parameters
Default
H0007
Default
K262,144
Default
K52,428,800