FX
-20SSC-H Positioning Block User's Manual
3U
DOG signal logic of servo
amplifier
Acceleration time 2 (Ver. 1.30 or later)
Deceleration time 2 (Ver. 1.30 or later)
X-DOG
Y-DOG
Mechanical zero return
command
Simultaneous START flag
Acceleration/deceleration time
change command
(Ver. 1.30 or later)
Current address (user)
Current address (pulse)
Zero return complete
Positioning completion
Zero phase passed
Function selection C-4
Note
• The zero return command is not accepted if the zero-point pass signal servo status is OFF.
Before executing zero return, be sure to rotate the servomotor at least once to turn the zero-point pass
signal ON. The zero-point pass signal turns ON when the motor passes the motor reference position signal
(Z-phase).
To execute zero return immediately after power-on, specify "1: Motor Z-phase pass unnecessary after
power-on" (default setting) at servo parameter function selection C-4. With this setting, the zero-point pass
signal turns ON even if the motor does not pass the zero-point (Z-phase).
• With the simultaneous start flag ON, the X-axis mechanical zero return command simultaneously starts the
X and Y-axes mechanical zero return operation.
(The 20SSC-H ignores the Y-axis mechanical zero return command.)
DOG position
Install the DOG at a position far enough from the stopper for the work piece to decelerate to the zero-point
return speed (creep).
2. Changing the zero return speed
Use the override function or operation speed change function to change the zero return speed (high speed).
However, the speed does not change when the operation speed change disable flag is ON.
140
External input selection BFM #14044 b9
BFM #14108
BFM #14110
Operation command 1
BFM #518 b6
Operation command 1
BFM #518 b10
Operation command 2
BFM #519 b5
BFM #1,#0
BFM #3,#2
Status information
BFM #28 b3
Status information
BFM #28 b6
Servo status
BFM #63 b0
Servo parameters
BFM #15080
(Advanced setting)
→ For the override function, refer to Subsection 7.6.1
→ For the operation speed change function, refer to Subsection 7.6.2
8.1 Mechanical Zero Return Control
BFM Number
X-axis
Y-axis
BFM #14244 b9
BFM #14308
BFM #14310
-
-
-
-
BFM #618 b6
BFM #619 b5
BFM #101,#100
BFM #103,#102
BFM #128 b3
BFM #128 b6
BFM #163 b0
BFM #15280
8 Manual Control
Data type
Positioning parameters
Positioning parameters
Positioning parameters
Input terminal (20SSC-H)
Input terminal (20SSC-H)
Control data
Control data
Control data
Monitor data
Monitor data
Monitor data
Monitor data
Monitor data
Servo parameters

Advertisement