Real Current Address (User) [Bfm #21, #20, Bfm #121, #120]; Real Current Address (Pulse) [Bfm #23, #22, Bfm #123, #122]; Received Target Address [Bfm #25, #24, Bfm #125, #124]; Received Target Speed [Bfm #27, #26, Bfm #127, #126] - Mitsubishi FX3U-20SSC-H User Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U

11.3.13 Real current address (User) [BFM #21, #20, BFM #121, #120]

The Real current address data is stored in units specified by the user
BFM Number
X-axis
Y-axis
BFM
BFM #21,#20
#121,#120
*1.
Refer to the section shown below for details on the user units.
POINT
• The real current address (user) is "Current address (user) - Deviation counter."
• Units specified by the user are adopted, and the position data magnification is included.

11.3.14 Real current address (Pulse) [BFM #23, #22, BFM #123, #122]

The Real current address is converted into pulses and stored. (Ver.1.20 or later)
BFM Number
X-axis
Y-axis
BFM
BFM #23,#22
#123,#122
POINT
• The real current address (pulse) is "Current address (pulse) - Deviation counter."

11.3.15 Received target address [BFM #25, #24, BFM #125, #124]

The target address for the positioning operation currently being executed is stored in units specified by the
*1
user
. (Ver.1.20 or later)
BFM Number
X-axis
Y-axis
BFM
BFM
#25,#24
#125,#124
*1.
Refer to the section shown below for details on the user units.
POINT
• The target address for the table number currently being executed is stored during table operation.
• Variable speed operation is not supported.

11.3.16 Received target speed [BFM #27, #26, BFM #127, #126]

The target speed for the positioning operation currently being executed is stored in units specified by the
*1
user
. (Ver.1.20 or later)
BFM Number
X-axis
Y-axis
BFM
BFM
#27,#26
#127,#126
*1.
Refer to the section shown below for details on the user units.
POINT
• The target speed for the table number currently being executed is stored during table operation.
Description
-2,147,483,648 to 2,147,483,647 (user unit)
Description
-2,147,483,648 to 2,147,483,647 PLS
Description
-2,147,483,648 to 2,147,483,647 (user unit)
Description
-2,147,483,648 to 2,147,483,647 (user unit)
11 Buffer Memory (Parameters & Monitored Data)
*1
. (Ver.1.20 or later)
Value Format
*1
Decimal
→ Refer to Section 7.10
Value Format
Decimal
Value Format
*1
Decimal
→ Refer to Section 7.10
Value Format
*1
Decimal
→ Refer to Section 7.10
11.3 Monitor Data
11
Default
12
-
13
A
Default
-
B
Default
-
Default
-
229

Advertisement

Table of Contents
loading

Table of Contents