Current address change function

With this function, the current address of a stopped axis changes arbitrarily.
Write the desired value to the current address (user) to change, followed by the current address (pulse)
update.
Note
The current address does not change in the following states.
• READY/BUSY in the status information is OFF (0).
• Interruption due to a STOP command occurs and the operation is waiting for the remaining distance.
Current address (user)
Current address (pulse)
READY/BUSY
Standby for remaining
travel distance at stop

7.9.10 Zero return interlock function

This function disables the start command before mechanical return.
1. Applicable positioning operations
• Operations applicable to the zero return
interlock setting
- 1-speed positioning operation
- Interrupt 1-speed constant quantity feed
- 2-speed positioning operation
- Interrupt 2-speed constant quantity feed
- Interrupt stop
- Multi-speed operation
- Linear interpolation
- Linear interpolation (interrupt stop)
- Table operation (individual)
- Table operation (simultaneous)
- Reciprocal movement instruction
(Ver. 1.10 or later)
2. Setting items
When using the zero return interlock function, set to ON the "zero return interlock setting enabled/disabled"
bit.
Zero return
interlock setting
enabled/disabled
Zero return
complete
Condition disabling the zero return interlock function
The zero return interlock function is disabled in the following cases:
• When the "zero return interlock setting enable/disabled" bit is set to "OFF"
• When the "zero return complete" flag is ON
118
→ For parameters, control data and monitor data, refer to Chapter 11
Status information
Status information
→ For the parameters, control data and monitor data, refer to Chapter 11
BFM Number
X-axis
Operation
BFM #14002
parameter 2
b2
Status
BFM #28 b3
information
BFM Number
X-axis
Y-axis
BFM #1, #0
BFM #101, #100 Monitor data
BFM #3, #2
BFM #103, #102 Monitor data
BFM #28 b0
BFM #128 b0
BFM #28 b7
BFM #128 b7
• Operations inapplicable to the zero return
interlock setting
- JOG operation
- Manual pulse generator operation
- Mechanical zero return
- Variable speed operation
Y-axis
Enables or disables the OPR interlock function.
1(ON):
Enable
BFM #14202
Disables the START command without zero return
b2
completion. Enables the START command with zero
return completion (zero return completed: ON)
0(OFF): Disable
Turns ON upon completion of mechanical zero return operation, or
when the current position is established by the absolute position
detection system.
BFM #128 b3
Turns OFF at OFF-to-ON transition of a mechanical zero return
command, at power-off (reset), or when an absolute position is
lost during the absolute position detection system.
7 Before Starting Positioning Operation
7.9 Other functions
Data type
Monitor data
Monitor data
Description