7.
Enter the name of the primary operator of this SMP 351 unit into the User name: field.
8.
Enter the password for that user into the Password field. To display text instead of dots
for the password, select (check) the Show Password check box.
9.
Enter a bit rate (in Kbps) in the Transfer Max Bitrate field, or use the Up and Down
arrows to change the value.
10.
Click Save, or click Cancel to discard the changes.
11.
If desired, click Test Connection Settings to make sure the settings you entered
in steps 3 through 9 work correctly. The status of the connection to the server and
directory are indicated below the button. A working connection is indicated by a check
(tick) mark within a green disk.
If you attempt to connect to a CIFS/Windows Net Share server with a Microsoft Windows 7
operating system, you may receive a drive mounting error message indicating that the
system cannot allocate memory. To resolve the error and make it possible to connect to the
server, do the following:
1.
Reset two registry keys on the Windows-based server:
a.
Set
HKLM\SYSTEM\CurrentControlSet\Control\Session Manager\Memory
Management\LargeSystemCache
b.
Set
HKLM\SYSTEM\CurrentControlSet\Services\LanmanServer\Parameters\
to 3.
Size
2.
Restart the server hardware or restart the Windows Server service.
Set a default recording file name
The SMP 351 uses a combination of information from fields defined in this pane to create
the file name for each recording. To set the default recording names:
1.
In the System Settings page, click the Expand button for the Default
Recording File Names pane to expand it. The pane opens.
2.
Select a type of information or metadata from the Configurable Field 1 and
Configurable Field 2 drop-down lists. Available options are:
Not Used
Event Course Name
Event Instructor Name
Event course name, event instructor name, and event title draw information from
the corresponding metadata fields as defined during ad hoc recording setup or in
imported recording schedules.
System location and system name information are set in the
Unit Identification pane within the System Settings page.
NOTE: Configurable Field 1 cannot be blank. If Not Used is selected, the field is
automatically populated with "Adhoc" for unscheduled recordings, or "Sched" for
scheduled recordings.
to 1.
Event Title
System Location
System Name
SMP 351 • Web-Based User Interface